Synergy Series Operation Guide (v18)
Keying • 7–47
4. Press
ENTER
to accept the new rate.
The display updates as shown below, the
ENTER
light turns off, and the new rate is
available for use.
This completes the procedure to change the MLE Rate.
Key Auto Transition Notes
Please note the following important points regarding key auto transitions:
•
An auto transition, once in progress, cannot
be paused.
•
To “escape” from an auto transition in progress, you can either press
CUT
during the
transition, or manually pull the
Fader
in the proper direction. The “cut” action instantly
completes the transition.
•
In a single MLE, you cannot
initiate an auto transition if the
Fader
is off its upper or
lower limit. If this effect is required, use a re-entry setup on the panel. Refer to the
section “
” on page 7–47 for additional details.
•
In a single MLE, you cannot
initiate a keyer auto transition if an auto transition in the
MLE Transition Group
is already in progress. If this effect is required, use a re-entry
setup on the panel.
•
If the
TRANS LIMIT
function is enabled and the transition is at the selected limit, you
cannot
initiate a keyer auto transition. If this effect is required, use a re-entry setup on
the panel.
•
The keyer’s
CUT
and
AUTO TRANS
buttons are linked to those in the
MLE
Transition Group
. When you press
AUTO TRANS
in a keyer, the
DISS
,
AUTO
TRANS
and appropriate “key” next transition button lights in the
MLE Transition
Group
— to indicate a key transition in progress. When the transition is finished, the
buttons return to their previous states.
•
Remember that you can transition the key with two different rates, depending on where
you press the
AUTO TRANS
button — either in the
Keyer
or in the
MLE Transition
Group
.
•
You cannot
wipe
a key using the buttons in the
Key 1
or
Key 2
group. This function
must be performed in the
MLE Transition Group
.
Key Cut Notes
Key “cut” transitions (using the
CUT
buttons in the
MLE Keyer
groups and
DSK
groups) can be
performed when the Fader is off its upper or lower limit. However, auto transitions (using the keyer
AUTO TRANS
buttons) cannot be performed at all when the fader is off a limit, or when an auto
transition is in progress.
Operating
Tip
If you do not want to change the auto transition rate at this time, press
any of the
RATE
or
STORE
buttons to cancel entering a new rate.
If you want to enter a
different
rate prior to pressing
ENTER
, simply
continue to type until the desired value appears.
REG:00 Memory0
MLE:015 KEY:008
Содержание SYNERGY 4000DR-003
Страница 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Страница 10: ......
Страница 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Страница 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Страница 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Страница 242: ...7 68 Keying Synergy Series Operation Guide v18...
Страница 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Страница 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...