![Ross SRG-2200 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/ross/srg-2200/srg-2200_user-manual_1488968019.webp)
SRG-2200 User Guide (v6.0)
Physical Installation • 19
Connecting Power
The SRG-2200 operates from an externally su12V DC power source. A safety earth stud is provided for
earth bonding the chassis if you so require.
Your SRG-2200 includes 2 ex12V power supply block to provide you will full redundancy. Note that you
need to provide two power connections. For full power security, these should be on separate, independent and
secure power grids. However, you still gain the security of power supply failure redundancy if you use the same
power grid for both connections.
Connecting the Power Cable
Connect the power cable to the instrument first, and then connect it to the AC power source. Note that connecting a
live power cable causes the instrument to power on.
Replacing a Power Supply
Since DC power is provided from an external supply, if you need to replace a power supply, simply replace the
faulty external PSU.
Setting the Initial IP Address
The SRG-2200 is remotely controlled over an Ethernet link by a DashBoard client.
When using DashBoard to communicate with the SRG-2200, the SRG-2200 is always configured as a fixed IPv4
device using the Dashboard in conjunction with DIP switches
SW1
and
SW2
on the rear panel.
Configuring the DIP Switches
This section briefly summarizes the DIP Switch settings on the SRG-2200.
OFF
position.
Figure 4.2 DIP Switches on SRG-2200 Rear Panel
SW1
and
SW2
are used in conjunction with the DashBoard menus to set the IP Address of the card. Refer to
and the rear panel labeling for DIP Switch positions.
Caution
— The SRG-2200 does not have a power switch.
Table 4.1 SW1 and SW2 Positions
SW1
Position
SW2
Position
Descriptions
OFF
OFF
The SRG-2200 network settings can be set by the user from
DashBoard (default).
OFF
ON
No functionality.
ON
OFF
The SRG-2200 IP Address is set to 192.168.2.1 The SRG-2200
Subnet Mask is set to 255.255.255.0.
ON
ON
The SRG-2200 IP Address is set to 10.1.2.1. The SRG-2200 Subnet
Mask is set to 255.255.255.0.
1
3
4
2
ON
Содержание SRG-2200
Страница 1: ...SRG 2200 User Guide...
Страница 8: ...iv Contents SRG 2200 User Guide v6 0...
Страница 14: ...14 Before You Begin SRG 2200 User Guide v6 0...
Страница 32: ...32 Functional Check Procedures SRG 2200 User Guide v6 0...
Страница 66: ...66 Specifications SRG 2200 User Guide v6 0...
Страница 72: ...72 Characters for Idents SRG 2200 User Guide v6 0...
Страница 88: ...88 NTP Option SRG 2200 User Guide v6 0...
Страница 94: ...94 Service Information SRG 2200 User Guide v6 0...
Страница 96: ...96 Glossary SRG 2200 User Guide v6 0...