18 • Physical Installation
SRG-2200 User Guide (v6.0)
The SRG-2200 does not currently have an internal fan to assist with ventilation or cooling. Therefore, when you
install the unit in an equipment bay, it is imperative that you ensure there is sufficient space all around the unit to
allow the airflow to vent away any excess heat generated by the unit.
Rack Mount Installation
You can install the SRG-2200 into an equipment rack. It is recommended to use the rack mount kit and to loom the
cables so that they do not introduce extra weight or twisting force on the front panel rack mountings or rear panel
connectors. If installed in a mobile application, the rack mount kit is essential.
This section describes how to install the SRG-2200 into the rack.
Installing the SRG-2200 into a Rack Unit
The SRG-2200 mounts in the rack cabinet by means of four screws through the front mounting flanges. This should
normally be sufficient to carry the load, including weight of cables. Refer to the
SRG-2200 Quick Start Guide
for
mounting details.
Installing the Rear Support Brackets
In some cases, (mobile trucks, etc.) it may be desirable to also support the rear of the SRG-2200. The rear support
bars can be attached to the SRG-2200 in six possible positions. (
Figure 4.1 Installing the Support Brackets
To install the support brackets
1. Choose the position that suits the cabinet depth and will give approximately a 0.5” projection beyond the
previously mounted bracket. The frame support bars can work with racks up to 26” deep.
2. Using four screws per bracket, as shown in
, attach both bars.
3. Mount the frame to the front rails of the rack cabinet using rack screws.
4. At the rear of the cabinet, slide the bracket slots over the rear of the support bars and secure to the cabinet rear
rails with rack screws.
Caution
— The SRG-2200 could be damaged if it is powered on at temperatures or humidities outside
the specified ranges.
Warning
— Do not use the support brackets to carry the SRG-2200. The brackets are not primarily
designed for this purpose, and property damage or personal injury may result.
One Rack-Unit (1RU)
Mounting Frame
Side View
Rack Cabinet
Rear View
Cabinet
Front Vertical
Mounting Rail
Cabinet
Rear Vertical
Mounting Rail
Cabinet
Left Rear Vertical
Mounting Rail
Cabinet
Right Rear Vertical
Mounting Rail
0.500”
Rear Support Bar
Bracket
Allow approximately 0.500” of the end of the
Rear Support Bar to project beyond the Bracket
Select a mounting position
that allows Rear Support Bars
to slide into slots of Brackets
Содержание SRG-2200
Страница 1: ...SRG 2200 User Guide...
Страница 8: ...iv Contents SRG 2200 User Guide v6 0...
Страница 14: ...14 Before You Begin SRG 2200 User Guide v6 0...
Страница 32: ...32 Functional Check Procedures SRG 2200 User Guide v6 0...
Страница 66: ...66 Specifications SRG 2200 User Guide v6 0...
Страница 72: ...72 Characters for Idents SRG 2200 User Guide v6 0...
Страница 88: ...88 NTP Option SRG 2200 User Guide v6 0...
Страница 94: ...94 Service Information SRG 2200 User Guide v6 0...
Страница 96: ...96 Glossary SRG 2200 User Guide v6 0...