background image

Specifications 

In This Chapter 

This chapter contains the Technical Specifications table. 

Technical Specifications 

 

Table 2. Technical Specifications 

Category 

Parameter 

Specification 

Number Of Inputs 

Standards 

SMPTE 259M, DVB/ASI formats, NRZ or NRZI 

Input Impedance 

75

 Terminating 

Return Loss 

>30dB @ 19MHz >20dB 143 - 360MHz 

Equalization 

Automatic up to 31dB (305m of Belden 8281 @ 
270Mb/s)* 

SDI Input 

Common Mode Rejection 

>10Vp-p @ 50/60Hz 

Number Of Outputs 

Output Impedance 

75

 

Return Loss 

>30dB @ 19MHz  >19dB 143 - 360MHz 

Signal Level 

800mV +/- 10% 

DC Offset 

0 Volts +/- 50 mV 

Rise and Fall Time (20 - 80%) 

800ps Typical 

Overshoot >8% 

SDI Outputs 

Delay (SDI Input to SDI Output) 

>6ns 

Power 

Total Power Consumption 

<1.7W 

*  We recommend 200m or less of input cable due to jitter considerations 

Specifications are subject to change without notification.   

SEA-8008 User Manual (Iss. 05A) 

Specifications  

  4-1 

Содержание SEA-8008

Страница 1: ...Ross Video Limited SEA 8008 Serial Equalizing Amplifier User Manual Ross Part Number 8008DR 004 Issue 05A...

Страница 2: ...ighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as a commitment by Ross Vide...

Страница 3: ...quipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or as...

Страница 4: ...th Canadian ICES 003 Cet appareil numerique de classe A est conforme la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of...

Страница 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Страница 6: ......

Страница 7: ...llation 2 2 BNC Labels 2 2 Cable Connections 2 2 LEDs 2 3 SMPTE 269M Fault Reporting 3 1 In This Chapter 3 1 Overview 3 1 Jumper Setup 3 2 Frame Connections 3 2 Details 3 2 Specifications 4 1 In This...

Страница 8: ...ii Contents SEA 8008 User Manual Iss 05A...

Страница 9: ...eo s experience in engineering and design expertise since 1974 You will be pleased at how easily your new SEA 8008 fits into your overall working environment Equally pleasing is the product quality re...

Страница 10: ...ul feature of the SEA 8008 is the card edge LED status indicators which confirm the presence of an input signal capable of equalization The SEA 8008 operates on all serial digital standards from 143Mb...

Страница 11: ...rms are used throughout this guide Frame refers to the DFR 8104A and DFR 8110A frames that house the SEA 8008 card All references to the DFR 8104A and DFR 8110A also include the DFR 8104A C and DFR 81...

Страница 12: ...1 4 Introduction SEA 8008 User Manual Iss 05A...

Страница 13: ...emiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wearing synthetic fiber clothing Always exercise proper grounding precautions when workin...

Страница 14: ...8 card by the edges and carefully align the card edges with the slots in the frame Then fully insert the card into the frame until the rear connection plug is properly seated BNC Labels Affix the supp...

Страница 15: ...t the module is operating correctly This indicates that the input signal is suitable for achieving error free performance and is within the capability of the cable equalizer to restore the signal ERRO...

Страница 16: ...2 4 Installation and Setup SEA 8008 User Manual Iss 05A...

Страница 17: ...TE 269M fault reporting The card connects by means of an internal interface circuit to an auxiliary telco connector on RossGear 8000 series frames When the frame connection is interfaced with a custom...

Страница 18: ...MPTE 269M Fault Reporting connection on RossGear 8000 series frames is provided by the auxiliary telco connector AUX A for interfacing with a customer designed alarm system AUX A Connector for SMPTE 2...

Страница 19: ...Automatic up to 31dB 305m of Belden 8281 270Mb s SDI Input Common Mode Rejection 10Vp p 50 60Hz Number Of Outputs 8 Output Impedance 75 Return Loss 30dB 19MHz 19dB 143 360MHz Signal Level 800mV 10 DC...

Страница 20: ...4 2 Specifications SEA 8008 User Manual Iss 05A...

Страница 21: ...Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power source and that po...

Страница 22: ...mation for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear SEA 8008 are to be conducted only by an authorized Ross Video Limite...

Страница 23: ...ucts Frame with Cooling Fan Module and Power Supply PS 8102 1RU holds 4 modules includes 1 power supply DFR 8110A Digital Products Frame and Power Supply PS 8102 2RU holds 10 modules includes 1 power...

Страница 24: ...fter hours Emergency 613 652 4886 ext 333 PHONE Fax 613 652 4425 General Information solutions rossvideo com E MAIL Technical Support techsupport rossvideo com Ross Video Limited 8 John Street Iroquoi...

Отзывы: