Ross PS-8102 Скачать руководство пользователя страница 8

ii • Contents

DFR-8110A(-C) User Manual (Iss. 03)

Содержание PS-8102

Страница 1: ...Ross Video Limited DFR 8110A C Digital Products Frame and Power Supply PS 8102 User Manual...

Страница 2: ...446 7 834 886 7 914 332 This product is protected by the following Canadian Patents 2039277 1237518 1127289 Other patents pending Notice The material in this manual is furnished for informational use...

Страница 3: ...s intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product Failure to heed this information may present a ris...

Страница 4: ...a norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93 68 EEC INTERNATIONAL This equipment has been tested to...

Страница 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Страница 6: ...O Box 880 Ogdensburg New York USA 13669 0880 General Business Office 1 613 652 4886 Fax 1 613 652 4425 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail Technical Support t...

Страница 7: ...g Performance 2 4 Ventilation and Cooling 2 4 Cabling for the DFR 8110A C 2 6 Cabling Overview 2 6 Optional Field Upgrade Kits 3 CFM 8110A Cooling Fan Overview 3 2 Installing the CFM 8110A 3 2 CRB 811...

Страница 8: ...ii Contents DFR 8110A C User Manual Iss 03...

Страница 9: ...f products backed by Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new DFR 8110A C fits into your overall working environment Equally pl...

Страница 10: ...glitch while maintaining a full power output This is of great importance in areas where incoming power may not be clean Features The following features make the DFR 8110A C one of the finest digital...

Страница 11: ...o the frame with the CFM 8110A Cooling Fan Module DFR 8110A C refers to all versions of the frame unless otherwise noted Operator and User refer to the person who uses DFR 8110A C Board and Card refer...

Страница 12: ...1 4 Introduction DFR 8110A C User Manual Iss 03...

Страница 13: ...allation 2 1 Installation In This Chapter This chapter provides instructions for installing the DFR 8110A C and cabling details The following topics are discussed Before You Begin Installing the DFR 8...

Страница 14: ...ved from the shipping container and ensure that all items are included If any items are missing or damaged contact your sales representative or Ross Video directly ESD Susceptibility Static discharge...

Страница 15: ...supply off before inserting or removing it from the frame will increase the life span of connectors Of great importance to the user who may have unstable or unpredictable facility power is the ability...

Страница 16: ...nstalled should not exceed 40 Watts and to leave an empty 1RU panel space above and below the frame for improved heat dissipation For information on the power requirements of RossGear modules please r...

Страница 17: ...performance it is recommended that the frame door not be opened for longer than 5 minutes when using the Cooling Fan Module option on frames loaded with more than 40 Watts Figure 2 1 Frame Stacking CF...

Страница 18: ...the frame connect to an opto isolator circuit in the frame For example in the case of the SRA 8001A Serial Auto Reclocking Amplifier if the input signal is lost or low the INPUT STATUS Red LED will b...

Страница 19: ...l that is distributed across the back plane to all modules Typically analog black video is used Some cards which need an external reference can use this master reference signal in place of taking the...

Страница 20: ...2 8 Installation DFR 8110A C User Manual Iss 03...

Страница 21: ...al Iss 03 Optional Field Upgrade Kits 3 1 Optional Field Upgrade Kits In This Chapter This chapter contains the following sections CFM 8110A Cooling Fan Overview CRB 8110A Card Retaining Bracket Suppo...

Страница 22: ...oard to the side of the frame by inserting the two Screws 850 075 provided from the left side of the frame exterior In mobile applications secure screws with Loctite 3 Remove the protective film from...

Страница 23: ...re to install the CRB 8100A 1 Install two plastic spacers on the threaded studs near bottom of the door Figure 3 2 Figure 3 2 CRB 8110A Installation 2 Mount the spacers to the door lower studs through...

Страница 24: ...procedure to install the FSB 7110 for the DFR 8110A C 1 Choose the position that suits the cabinet depth and will give approximately inch projection beyond the rear vertical mounting rails 2 Using fou...

Страница 25: ...User Manual Iss 03 Specifications 4 1 Specifications In This Chapter This chapter provides the technical specification information for the DFR 8110A C The following topics are discussed Technical Spe...

Страница 26: ...requiring greater heat dissipation Table 4 1 DFR 8110A C Technical Specifications Category Parameter Specification Power Supply Input Voltage 100 240VAC 50 60Hz Input Power 2RU DFR 8110A 130W Output V...

Страница 27: ...DFR 8110A C User Manual Iss 03 Service Information 5 1 Service Information In This Chapter This chapter contains the following sections Troubleshooting Checklist Warranty and Repair Policy...

Страница 28: ...me and any associated peripheral equipment for signs of trouble 2 Power Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illu...

Страница 29: ...ear DFR 8110A C User Manual provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear DFR 8110A C...

Страница 30: ...Notes...

Страница 31: ...Notes...

Страница 32: ...on Related products and full product lines On line catalog News Testimonials Ross Part Number 8110ADR 004 03 PHONE General Business Office and Technical Support 613 652 4886 After Hours Emergency 613...

Отзывы: