Ross MC1-MK Скачать руководство пользователя страница 2

2

Technical Support: (+1) 613-652-4886

After Hours Emergency: (+1) 613-349-0006

E-mail: [email protected] 

For More Information on...

• specific cabling requirements and pinouts, refer to the Dasdec-2 user documentation.

Connecting the Comtrol DeviceMaster to the Dasdec-2

The Digital Alert Systems Dasdec-2 connects to the Comtrol DeviceMaster via the RS-232 serial port on 

the Dasdec-2 and an available serial port on the Comtrol DeviceMaster.

You will need a DB-9 female to DB-9 female null modem cable. Ross Video does not supply this 

cable.

Refer to 

Table 1

 for the required Serial RS-232 pinout designations.

Refer to 

Table 2

 for pinout designations on each serial port.

Proceed to connect the MC1-MK to the Digital Alert Systems Dasdec-2. 

Connecting the Dasdec-2 to the MC1-MK

There are two cabling options for establishing communications between the MC1-MK and the Digital 

Alert Systems Dasdec-2: Serial or TCP/IP. Both methods are described in this section.

Serial Connection

The Digital Alert Systems Dasdec-2 connects to the MC1-MK via an available serial port (RS-232) on the 

Dasdec-2 and the SERIAL port (RJ45) on the MC1-MK rear module. 

You will need a DB-9 female to RJ45 cable. Ross Video does not supply this cable.

Refer to 

Table 1

 for the required Serial RS-232 pinout designations.

Table 1  Dasdec-2 to Comtrol DeviceMaster Pinouts

Dasdec-2

Comtrol DeviceMaster

Pin 3 (Tx)

Pin 2 (Rx)

Pin 2 (Rx)

Pin 3 (Tx)

Pin 5 (GND)

Pin 5 (GND)

Table 2  Dasdec-2 and Comtrol DeviceMaster Port Designations

Dasdec-2 (DB9 Male)

Comtrol DeviceMaster (DB9 Male)

Содержание MC1-MK

Страница 1: ...the MC1 MK 1 Communications connection Serial or TCP IP via Comtrol DeviceMaster to provide EAS crawl text 2 EAS Voice Over connection using an GPI to the MC1 MK 3 Analog or AES audio connection to pr...

Страница 2: ...ort Proceed to connect the MC1 MK to the Digital Alert Systems Dasdec 2 Connecting the Dasdec 2 to the MC1 MK There are two cabling options for establishing communications between the MC1 MK and the D...

Страница 3: ...s are specified on the Digital Alert Systems Dasdec 2 Set the SERIAL port on the Dasdec 2 to Sage Generic CG Refer to Table 5 for additional serial settings For More Information on configuring your Da...

Страница 4: ...ay programming 3 Configure the GPO RELAY port on the Dasdec 2 for EAS Audio Playout MC1 MK Audio Connections When connecting the MC1 MK MK to the Digital Alert Systems Dasdec 2 you will also need one...

Страница 5: ...the Dasdec 2 audio to two or more channels as required b Disable the Audio Groups and mute the channels that are not used 5 Select the AES or Analog Inputs tab 6 Configure the Delay and Gain as requir...

Страница 6: ...le for EAS audio voice over support To enable EAS audio voice over 1 Select the GPI Tally tab 2 Locate the row for the MC1 MK GPI port you connected to the GPO RELAY port on the Dasdec 2 3 Select GPI...

Страница 7: ...you want to customize The following will occur once you select a category button For normal EAS operation set the Preview to OFF The EAS Setup tab settings display the stored values for the selected c...

Страница 8: ...8 Technical Support 1 613 652 4886 After Hours Emergency 1 613 349 0006 E mail techsupport rossvideo com...

Отзывы: