![Ross CARBONITE RCP Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ross/carbonite-rcp-series/carbonite-rcp-series_manual_1488796002.webp)
3.
Click
Refresh
.
A list of all RCP panels on the network is shown.
4.
Select the RCP panel that you want to set up.
Tip:
If you do not know which RCP is the one you want to
set up, click Locate for each RCP until the buttons on your
RCP panel start flashing. Click Locate again to stop the
buttons flashing.
5.
Enter the IP Address (
Address
), netmask
(
Netmask
), and gateway (
Gateway
) you want to
assign to the panel.
Tip:
You can also enter a name (Name) for the panel if
you want.
6.
Click
Reboot
to reboot the panel and apply the new
network settings.
When the panel reboots with the new network
settings it should be discovered by DashBoard and
appear in the
Basic Tree View
.
7.
Double-click the RCP node in the
Basic Tree View
to open the configuration window.
8.
In the
Servers to connect to
area, enter the IP
address of the NK-IPS that you want to connect it
to.
9.
Click
Send Configuration
.
Remote Control Panel Interface
From the Ross RCP-NK1 Remote Panel, you can select
video sources on Aux, Program, Preview, and Key buses
on the switcher, and run custom controls.
To Select a Source on a Bus from the Remote
Panel
1.
Select the level on the Remote Control Panel that is
assigned to the switcher.
2.
Select the button on the output section of the Remote
Panel that corresponds to the output BNC on the
switcher. Refer to the output mapping table for your
switcher.
3.
Select the button on the input section of the Remote
Panel that corresponds to the source on the switcher
you want to select. Refer to the input mapping table
for your switcher.
Selecting an input (or source) on the Remote Panel acts
like a selection of that source on the bus of the switcher.
Router Panel Output/Input Mapping
Note:
The mapping for the Carbonite Black operating in a
UHDTV1 video format is different from it operating in an SD/HD
format.
Note:
PGM ME refers to the ME that is set at the program ME
on the switcher, and could be ME 1 or ME 2, depending on the
configuration of your switcher.
Table 1: Router Control Panel Output Mapping
Carbonite Black
UHDTV1
Carbonite Black
SD/HD
Graphite
Carbonite
Router
Output
Aux 1-8
1-8
Aux 9-10
--
9-10
--
Aux 11-20
--
11-20
MiniME
™
1 Program
61
MiniME
™
1 Preview
62
MiniME
™
1 Key 1 Video+Alpha
63
MiniME
™
1 Key 2 Video+Alpha
64
MiniME
™
1 Key 1 Alpha
65
MiniME
™
1 Key 2 Alpha
66
MiniME
™
2 Program
67
MiniME
™
2 Preview
68
MiniME
™
2 Key 1 Video+Alpha
69
MiniME
™
2 Key 2 Video+Alpha
70
MiniME
™
2 Key 1 Alpha
71
MiniME
™
2 Key 2 Alpha
72
--
MiniME
™
3 Program
73
--
MiniME
™
3 Preview
74
--
MiniME
™
3 Key 1 Video+Alpha
75
--
MiniME
™
3 Key 2 Video+Alpha
76
--
MiniME
™
3 Key 1 Alpha
77
--
MiniME
™
3 Key 2 Alpha
78
--
MiniME
™
4 Program
79
--
MiniME
™
4 Preview
80
--
MiniME
™
4 Key 1 Video+Alpha
81
--
MiniME
™
4 Key 2 Video+Alpha
82
--
MiniME
™
4 Key 1 Alpha
83
--
MiniME
™
4 Key 2 Alpha
84
--
MultiScreen 1 Program
85
2