Auxiliary Control Panels

The information in this document applies to the
RCP-NK1, NK-IPS, and RCP-ME.

Cable Connections

The Ross

®

RCP-NK1 connects to the switcher through

an NK-IPS and NK-NET. The connection between the
NK-NET and the switcher is over ethernet.

The RCP-ME connects to the switcher directly over
ethernet.

T-BUS

Service
Port

POWER

ETHERNET

1

2

3

4

5

6

7

8

T-BUS

T-Bus Connections

Maximum 100m

cable length

Network connection

to Switcher

NK-IPS (rear)

RCP-NK1 (rear)

TB

US

NK-NET

ETHERNET

Figure 1: RCP-NK1 to Switcher Cabling

Refer to the documentation that came with your device
for safety and setup information.

Switcher Communications Setup

The switcher must be set up to communicate with the
aux panel using an ethernet protocol.

To Set Up Ethernet Communications

1.

Press

MENU

>

SYSTEM

>

NEXT

>

NEXT

>

Device Config

2.

Press

Add

and use the

Slot

knob to select an

ethernet connection (

Slot #

).

3.

Use the

Type

knob to select

RouterPanel

.

4.

Press

NEXT

.

5.

Use the

SubType

knob to select the driver for your

panel.

RCP-NK1

— select

NK-IPS_1.0

RCP-ME

— select

RCP_ETH_1.0

6.

Press

NEXT

.

7.

Note:

NK-IPS only. If you are setting up an RCP-ME skip

to setting the port value. You cannot set an IP address for
this device.

Use the

Field

knob to select the segment of the IP

address you want to edit and the

Value

knob to

select the number.

Note:

You must enter the IP address of the NK-NET that

you are using to communicate with the NK-IPS.

8.

Press

NEXT

.

9.

Use the

Option

and

Value

knobs to complete the

setup.

Value

Option

Port

RCP-NK1

— select the

Client

TCP Port

of the NK-IPS that the

RCP-NK1 is connected to.

RCP-ME

— select

5000

.

Select which level on the RCP panel
is controlling the switcher.

Level

10.

Press the

Option

knob and

Confirm

to add the

device.

Auxiliary Control Panel Setup

The aux panel must be set up to communicate with the
switcher using the same serial or ethernet
communications as you set the switcher up to use.

Note:

This information in this procedure is provided as a guide

and is based on the current version of hardware and software
that was available at the time of testing. For the most accurate
and up-to-date information, refer to the documentation that came
with your router.

Note:

The NK-IPS must be set with a gateway of

0.0.0.0

if there is no gateway configured on your network.

To Set Up Ethernet Communications

The information in this procedure is provided as a guide
and may not represent the current state of the RCP panels.
Refer to the documentation that came with your RCP
panel for the latest setup information.

1.

Connect the RCP to a network on the same subnet
as your DashBoard computer and the switcher.

2.

In DashBoard, click

File

>

Show Walkabout

.

4802DR-604 Rev.9

©

2017 Ross Video Limited. Ross

®

, MiniME , and any related marks are trademarks or registered trademarks of Ross Video Limited. All other trademarks are the property of their respective companies. PATENTS ISSUED and PENDING. All rights reserved. No part of

this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopying, recording or otherwise, without the prior written permission of Ross Video. While every precaution has been taken in the preparation
of this document, Ross Video assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.

RCP

Auxiliary Control Panels

Содержание CARBONITE RCP Series

Страница 1: ... 5000 Select which level on the RCP panel is controlling the switcher Level 10 Press the Option knob and Confirm to add the device Auxiliary Control Panel Setup The aux panel must be set up to communicate with the switcher using the same serial or ethernet communications as you set the switcher up to use Note This information in this procedure is provided as a guide and is based on the current ver...

Страница 2: ...tput BNC on the switcher Refer to the output mapping table for your switcher 3 Select the button on the input section of the Remote Panel that corresponds to the source on the switcher you want to select Refer to the input mapping table for your switcher Selecting an input or source on the Remote Panel acts like a selection of that source on the bus of the switcher Router Panel Output Input Mappin...

Страница 3: ...review 126 ME 2 Key 1 Video Alpha 127 ME 2 Key 2 Video Alpha 128 ME 2 Key 3 Video Alpha 129 ME 2 Key 4 Video Alpha 130 ME 2 Key 1 Alpha 133 ME 2 Key 2 Alpha 134 Carbonite Black UHDTV1 Carbonite Black SD HD Graphite Carbonite Router Output ME 2 Key 3 Alpha 135 ME 2 Key 4 Alpha 136 ME 3 Program ME 3 Program 139 ME 3 Preview ME 3 Preview 140 ME 3 Key 1 Video Alpha ME 3 Key 1 Video Alpha 141 ME 3 Key ...

Страница 4: ...el that is assigned to the switcher 2 Select the button on the output section of the Remote Panel that corresponds to the custom control bank that you want to run stop or resume a custom control on Refer to the following tables for bank mapping information 3 Select the button on the input section of the Remote Panel that corresponds to the custom control that you want to run stop or resume Refer t...

Отзывы: