Ross 4800DR-327 Скачать руководство пользователя страница 6

 5 • CompactFlash Replacement

Replacing the CompactFlash

To replace the CF, you must power down the Vision control panel, remove the 
CompactFlash access plate, remove the old CF, insert the new CF, and replace 
the CompactFlash access plate.

Use the following procedure to replace the CF in the Vision control panel:

1.

Power down the control panel. The frame can remain on during this 
procedure. Refer to your Vision switcher documentation for 
information on shutting down the control panel.

2.

Unplug the Primary and Redundant (if installed) power from the 
control panel.

Warning Hazardous Voltage

 — Hazardous voltages are 

present in the control panel as long as any of the power supplies 
are connected to the AC power.

3.

Lift up on the control panel lid to gain access to the control panel tub.

4.

Identify the 

CompactFlash Access Plate

 on the front of the Control 

Panel CPU Module (

Figure 1

).

Figure 1  CompactFlash Access Plate — Control Panel CPU Module

5.

Remove the screws from either side of the 

CompactFlash Access 

Plate

 and remove the plate from the Control Panel CPU Module. 

Store the screws and CompactFlash Access Plate in a safe place.

6.

Identify the 

CompactFlash

 installed in the CF Slot on the underside 

of the CPU Board (

Figure 2

).

Figure 2  CompactFlash

Compact Flash

Access Plate

Screw

Screw

PWR

RST

Compact Flash

Содержание 4800DR-327

Страница 1: ...Ross Video Limited CompactFlash Installation Guide V I S I O N ...

Страница 2: ...software is prohibited Notice The material in this guide is furnished for informational use only It is subject to change without notice and should not be construed as commitment by Ross Video Limited Ross Video Limited assumes no responsibility or liability for errors or inaccuracies that may appear in this guide Trademarks is a registered trademark of Ross Video Limited Ross ROSS ROSS and MLE are...

Страница 3: ...me to dissipate static charge before removing boards from the frame and exercise proper grounding precautions when working on circuit boards Environmental Information The equipment that you purchased required the extraction and use of natural resources for its production It may contain hazardous substances that could impact health and the environment To avoid the potential release of those substan...

Страница 4: ...ts Package Contents The contents of a CompactFlash replacement kit is listed below If any items are missing or damaged contact Ross Video Technical Support Qty Part Item 1 726 165R 4GB CompactFlash with Vision software ...

Страница 5: ...ettings Before you replace the CF you must navigate to the Network Setup Menu to record the network address of the control panel and the frame After you install the new CF you will use this information to re establish communications between the control panel and the frame Use the following procedure to record the network address of the control panel and frame 1 Navigate to the Network Setup Menu a...

Страница 6: ...l panel Warning Hazardous Voltage Hazardous voltages are present in the control panel as long as any of the power supplies are connected to the AC power 3 Lift up on the control panel lid to gain access to the control panel tub 4 Identify the CompactFlash Access Plate on the front of the Control Panel CPU Module Figure 1 Figure 1 CompactFlash Access Plate Control Panel CPU Module 5 Remove the scre...

Страница 7: ...own and slide it into the empty CF Slot until the Ejector Button pops out Figure 4 Figure 4 CompactFlash Insertion 9 Replace the CompactFlash Access Plate and install the screws in either side of the plate 10 Close the control panel lid and reconnect the power to the control panel This completes the procedure for replacing the CF in the Vision control panel Next you must power on the control panel...

Страница 8: ...starts ensure that the switcher has been upgraded to v8 2E software Perform the upgrade again if necessary You may have to point the frame to the default IP address of the Vision control panel 192 168 1 2 to perform the upgrade 2 Place the control panel into diagnostic mode by pressing HOME three times quickly 3 Navigate to the Network Setup Menu as follows Press HOME B More B Setup B More B Netwo...

Страница 9: ...es to control panel rows is stored on the CF When the new CF is installed the modules on the control panel must be re assigned Refer to your Vision Engineering Manual for information on upgrading your Panel Module Controllers PMCs and assigning the modules to a panel row ...

Страница 10: ...9 Control Panel Configuration Notes ...

Страница 11: ...Control Panel Configuration 10 Notes ...

Страница 12: ...Company information Related products and full product lines On line catalog News Testimonials PHONE General Business Office and Technical Support 613 652 4886 After Hours Emergency 613 349 0006 Fax 613 652 4425 E MAIL General Information solutions rossvideo com Technical Support techsupport rossvideo com POSTAL SERVICE Ross Video Limited 8 John Street Iroquois Ontario Canada K0E 1K0 Ross Video Inc...

Отзывы: