background image

IMPORTANT NOTE:

 

 Please read carefully and thoroughly all of the 

CAUTIONS, WARNINGS

 

on the inside back cover.

A7.5

www.rosscontrols.com

Online Version
Rev. 11/14/16

0.83

(21.1)

Single Connector Kit 609E94 (not included)

1/2 -14 NPT 

Inlet (Both sides)

1/2 -14 NPT 

Exhaust (Both sides)

4 x 

O

 .34 

Thru for Mounting

1/8 -27 NPT 

x 8 Outlets

7 x 

0.68 (17.3)

0.33

(8.4)

0.68 

(17.3)

4.9

(142.5)

2.03

(51.6)

3.53 ( 89.7)

0.9

(23.9)

1.20

(30.5)

120 (3048)

4.88 (124.0)

6.38

(162.1)

3.12

(79.3)

1.52

(38.6)

1.39

(35.3)

3.75 (95.3)

0.81

(20.6)

3/2 Normally Closed

1

2

3

12

Individual Valve Shut-off (automatic):  

Individual valves can be removed without shutting off 

main air supply to the whole manifold or entire solenoid cabinet.  

• 

Simply remove the valve and an internal check-ball automatically blocks inlet air to that station 

• 

Inlet air is automatically restored to the station when the valve is returned

Construction: 

 Poppet. 

Mounting Type: 

Base.

Solenoids: 

Rated for continuous duty.

Standard Voltages:  

24 volts DC; 110-120 volts AC, 50/60 Hz.  

Power Consumption: 

 

0.03 VA holding on 50/60 Hz; 0.8 watts on DC.

Enclosure Rating: 

 IP65, IEC 60529.

Electrical Connections:

 EN 175301-803 Form C connector.

Ambient Temperature: 

39° to 122°F (4° to 50°F).

Media Temperature: 

 

39° to 175°F (4° to 80°C).

Indicator Light:

  In connector.

Flow Media: 

Filtered air.

Inlet Pressure:  

30 to 150 psig (2 to 10 bar).

4/2 Low-Power Solenoid Pilot Controlled Valves available, consult ROSS.

STANDARD SPECIFICATIONS 

(for valves on this page)

:

3-Way 2-Position Valves - Extended-Duty, 

Single Solenoid Pilot Controlled

Valve/Manifold Assembly

Model Number

C

V

Flying Leads

Central Wiring

8 Station

3900A0713-1

**

3900A1055-1

**

0.5

16 Station

3900A0713-2

**

3900A1055-2

**

0.5

24 Station and over

consult ROSS 

consult ROSS

0.5

**

 Insert voltage code: “

W

” = 24 volts DC; “

Z

” = 110-120 volts AC, 50/60 Hz; 

e.g., 3900A1052-1

W

.  For other voltages, consult ROSS.

3-Way Solenoid Pilot Controlled Pack Valves

Pack Series

Fitting

Fitting Type

Port 

Threads

Model Number

*

Flying Leads

Central Wiring

Metal Swivel

1/8

322E27   

322E27

*

1/4 tube.

Electrical 
Connector

Connector Type

Model Number

Flying Leads

Central Wiring

EN 175301-803 Form C

609E94

consult ROSS

*

 Electrical Connector w/10’ leads.

A

CCessories

 & o

ptions

A7

A

Dimensions –

 inches (mm)

Silencers

Port 
Size

Thread 

Type

Model Number

NPT Threads

BSPT Threads

3/8

Male

5500A3013

D5500A3013

1/2

Male

5500A4003

D5500A3003

Pressure Range:  

0 to 150 psig (0 to 10.3 bar) maximum.

    

Flow Media: 

 Filtered air.

Содержание Miniature Valves W14 Series

Страница 1: ...ROSS CONTROLS www rosscontrols com Miniature Valves W14 Series Solenoid Pilot Pack Valves Series...

Страница 2: ...onditions dirt tolerant high humidity cold heat dust debris returned from the field actuator etc Easily Accessible Manual Override Yellow turn to actuate no tools needed Positive Sealing and Self Comp...

Страница 3: ...Insert voltage code W 24 volts DC Z 110 120 volts AC 50 60 Hz e g W1413A1408W For other voltages consult ROSS STANDARD SPECIFICATIONS for valves on this page Sub Base Port Threads Model Number 1 8 NPT...

Страница 4: ...tor Flow Media Filtered air Inlet Pressure 30 to 150 psig 2 to 10 bar For dual or spring return actuators Field convertible to a 3 2 Valve 5 Way 2 Position Valves Single Solenoid Pilot Controlled Valv...

Страница 5: ...nections EN 175301 803 Form C connector Ambient Temperature 39 to 122 F 4 to 50 F Media Temperature 39 to 175 F 4 to 80 C Indicator Light In connector Flow Media Filtered air Inlet Pressure 30 to 150...

Страница 6: ...alues the figures given in this catalog should not be used to compare ROSS valves with those of other makers The CV ratings given here are intended only for use with performance charts published by RO...

Страница 7: ...lly leading to valve failure which risks human injury and or damage to property AVOID INTAKE EXHAUST RESTRICTION 8 Do not restrict the air flow in the supply line To do so could reduce the pressure of...

Отзывы: