Страница 1: ...IDE Operation Maintenance and Service Parts RO FFG 115 N RO FFG 160 N RO FFG 115 P RO FFG 160 P EN Gas Floor Fryer RO FFG RO FFG 115 RO_FFG_GUIDE 08 22 955 rue Lachance Québec QC G1P 2H3 Canada 1 866 901 5624 www rosko julien ca 991002623 ...

Страница 2: ...tallation must meet the requirements of the codes below where applicable State codes or local codes or in the absence of local codes In the United States national gas code ANSI Z223 1 NFPA 54 In Canada installation code for natural gas CSA B149 1 or propane gas CSA B149 2 In Canada the electrical code CSA C22 1 Installation of this unit must be done by a qualified person where required by law Do n...

Страница 3: ...TION 11 3 3 CLOSING 12 3 4 DRAINAGE 12 4 CLEANING 13 4 1 SURFACE CLEANING 13 4 2 ACCESSORY CLEANING 13 4 3 FILTRATION 13 4 4 TANK CLEANING 14 5 PREVENTIVE MAINTENANCE 15 5 1 MINIMUM INSPECTION 15 5 2 PROFESSIONAL INSPECTION 15 6 TROUBLESHOOTING 16 6 1 GENERAL TROUBLESHOOTING 16 6 2 TROUBLESHOOTING CHART 17 7 SERVICE PARTS 18 7 1 RO FFG 115 N and RO FFG 115 P 18 7 2 RO FFG 160 N and RO FFG 160 P 20...

Страница 4: ...aterials 6 152 mm at the back of the unit 3 76 mm on each side of the unit Construction with non combustible materials 0 0 mm at the back and on each side of the unit Provide adequate space for the operation and maintenance of the unit 2 2 AIR SUPPLY AND VENTILATION Provide adequate ventilation above the unit You must always place the fryer under a ventilation hood to evacuate burnt gas fumes outs...

Страница 5: ...r damage resulting from improper installation inadequate operation or unauthorized service prior to installation Before installation make sure the gas floor fryer specifications match the type of gas supply Refer to the nameplate on the inside of the door Important Confirm that you have received all the parts included with your fryer model All Gas Floor Fryer models Material included 1 deep fryer ...

Страница 6: ...eable installation on casters purchase the RO ACC FFG 4W 4 caster set sold separately Caster installation instructions are included with the kit WARNING In the case of a moveable installation on casters the installation must meet the requirements of the standards below where applicable In the United States Standards for Connectors for Moveable Gas Appliances ANSI Z21 69 and Standards for Quick Dis...

Страница 7: ...supply hose to restrict fryer movement Attachment can be done by inserting the fryer into a battery of appliances or by securing the fryer to the back wall using a chain that is shorter than the gas supply pipe and a ring Figure 2 NOTE Attachment material is not included ATTACHMENT ...

Страница 8: ...r connection and before ignition open the gas supply valve and check the joints for any leaks with soapy water Never use a flame to check for gas leaks WARNING Installation must meet the requirements of the codes below where applicable State codes or local codes or in the absence of local codes In the United States national gas code ANSI Z223 1 NFPA 54 In Canada installation code for natural gas C...

Страница 9: ...e should be 3 5 W C for natural gas 10 W C for propane gas Make sure the burners are operating at maximum capacity while checking the pressure Operate all other equipment connected to the gas piping supply at maximum capacity then read the pressure 2 Shut off all other appliances and take a second pressure reading If the pressure varies by more than 1 W C install a pressure regulator not included ...

Страница 10: ... oil or grease 1 Close the ball valve located at the front of the fryer Figure 5 2 Fill the tank with 23 liters of oil or melted fat until the level is one 1 inch from the rear edge of the tank Figure 6 For use with solid fat be sure to follow the next steps to melt the fat 1 Remove the baskets and the screen from the tank 2 Cut the fat into slices thin enough to fit between the tubes 3 Fill the t...

Страница 11: ...3 Press and hold the gas control knob while manually lighting the pilot Figure 8 4 Hold the knob down for 45 seconds 5 If the pilot light does not stay on repeat the procedure 6 Place the gas control knob in the ON position 7 Set the thermostat knob to the desired temperature Figure 7 Figure 8 Figure 6 MAX OFF PILOT ON ARRÊT OFF 4 0 0 3 5 0 3 0 0 2 5 0 200 MAX ...

Страница 12: ... Wait for the oil or grease to cool before emptying the tank 2 Attach the 1 drain pipe to the ball valve located behind the door Figure 10 3 Place a container that is large enough to catch all of the used oil under the drain pipe 4 Open the ball valve and let the used oil or grease drain out 5 Securely close the ball valve OFF PILOT ON Figure 10 Figure 9 DRAIN PIPE Figure 7 ARRÊT OFF 4 0 0 3 5 0 3...

Страница 13: ...ryer accessories by hand using a commercial degreaser or with hot water and a commercial dishwasher The fry tank s baskets stand and screens should be cleaned every day after service Additional accessories such as a drip tray or lid should be cleaned weekly or when you clean the tank according to the broil out procedure 4 3 FILTRATION Remember to change and filter the oil or grease regularly to av...

Страница 14: ... open 2 Use a cleaning rod to clear the drain hole 3 Rinse off excess grease with hot water 4 Close the drain valve and add water to the back edge of the tank 5 Add a quantity of fryer tank cleaner 6 Gently bring the water to a boil for twenty 20 minutes 7 Turn off the unit and open the drain valve to let the water evacuate 8 Clean the fronts and tubes of the bowl with a fryer brush not included 9...

Страница 15: ... in particular take the form of poor quality yellow flames or the appearance of soot coming out of the chimney To avoid complications and ensure proper operation of the unit please contact a service company once 1 a year to apply Cleaning of the heat pipes Cleaning of the burner orifices Verification of the gas operating pressure 5 2 PROFESSIONAL INSPECTION This section is dedicated to authorized ...

Страница 16: ...ok that the thermopile is straight and at a distance of 5 mm from the pilot 6 2 TROUBLESHOOTING CHART This section is dedicated to authorized technicians only WARNING Only qualified service personnel should use the troubleshooting chart to repair this fryer Many operations require knowledge of the unit and precautions to be taken with the gas supply to avoid serious injury The problems and possibl...

Страница 17: ... 4 Ensure that the high limit contact is closed or change it according to section 7 5 Change the thermopile according to section 7 The burners do not light when the thermostat is turned on 1 The gas control knob is not positioned correctly 2 The devis gas pressure is not adjusted 3 The thermostat is defective 4 The gas control devise is defective 1 Ensure that the gas control is positioned to ON 2...

Страница 18: ...c Door Latch 1 7 935900035 Propane Gas Injector Hex 1 2 51 3 935900037 Natural Gas Injector Hex 1 2 34 3 8 935150056 Propane Gas Multifunction Gas Control 1 935150055 Natural Gas Multifunction Gas Control 1 9 913200021 Thermostat OFF 200 400 F 36 Capillary Tube 1 10 913900222 High Limit Safety Switch 460 F 1 11 913900220 Control Knob for Commutable Ring 1 12 913900221 Knob Ring for Control OFF 200...

Страница 19: ...19 RO_FFG_GUIDE 08 22 4 15 14 13 2 3 5 6 7 8 11 12 9 10 1 16 Figure 11 ...

Страница 20: ...0450015 Magnetic Door Latch 1 7 935900035 Propane Gas Injector Hex 1 2 51 4 935900037 Natural Gas Injector Hex 1 2 34 4 8 935150056 Propane Gas Multifunction Gas Control 1 935150055 Natural Gas Multifunction Gas Control 1 9 913200021 Thermostat OFF 200 400 F 36 Capillary Tube 1 10 913900222 High Limit Safety Switch 460 F 1 11 913900220 Control Knob for Commutable Ring 1 12 913900221 Knob Ring for ...

Страница 21: ...21 RO_FFG_GUIDE 08 22 2 3 13 6 7 8 11 12 9 10 1 4 5 14 15 Figure 12 ...

Страница 22: ...8 mm 48 1219 mm 42 lb 23 L 125 lb 57 kg 20 x 30 x 53 508 x 762 x 1346 mm RO FFG 115 P RO FFG 160 N 20 508 mm 285 8 726 mm 60 lb 34 L 168 lb 76 kg 24 x 36 x 53 610 x 914 x 1346 mm RO FFG 160 P Models Total output Number of burners Gas type supply Operating presure RO FFG 115 N 115 000 BTU H 3 Natural 3 5 po W C RO FFG 115 P Propane 10 po W C RO FFG 160 N 160 000 BTU H 4 Natural 3 5 po W C RO FFG 16...

Страница 23: ...RO_FFG_GUIDE 08 22 9 ELECTRICAL DIAGRAM 13 13 955 rue Lachance Québec Québec G1P 2H3 Canada T 1 800 461 3377 418 687 3630 F 1 866 397 9090 418 687 9090 DIAGRAMME ÉLECTRIQUE ELECTRICAL DIAGRAM FG 115 FG 160 ...

Страница 24: ...24 RO_FFG_GUIDE 08 22 955 rue Lachance Québec QC G1P 2H3 Canada 1 866 901 5624 www rosko julien ca CONTACT US customerservice rosko julien ca ...