8
Problem
Possible cause
Solution
The compressor operates
continuously.
Temperature is set incorrectly.
Refer to “Operation” chapter.
Many food products to be frozen
were put in at the same time.
Wait some hours and then check the
temperature again.
The room temperature is too high.
Refer to climate class chart on the
rating plate.
Food products placed in the appli-
ance were too warm.
Allow food products to cool to room
temperature before storing.
The lid is not closed correctly.
Clean the door gaskets. If necessary,
adjust the door.
There is too much frost and ice.
The lid is not closed correctly or the
gasket is deformed/dirty.
Clean the door gaskets. If necessary,
adjust the door.
The water drainage plug is not cor-
rectly positioned.
Position the water drainage plug in the
correct way.
Temperature is set incorrectly.
Refer to “Operation” chapter.
The temperature in the
appliance is too low/too high
The temperature regulator is not set
correctly.
Set a higher/lower temperature.
The lid is not closed correctly.
Clean the door gaskets.If necessary,
adjust the door.
The food products temperature is
too high.
Let the food products temperature
decrease to room temperature before
storage.
Many products are stored at the
same time.
Store less products at the same time.
The thickness of the frost is greater
than 4-5 mm.
Defrost the appliance.
The lid has been opened often.
Open the lid only if necessary.
There is no cold air circulation in the
appliance.
Make sure that there is cold air circula-
tion in the appliance.