Installation Instruction
for
½”
annular corrugation cable
MA_1C7-C03_U
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.
: +49 8684 18-0
Email : [email protected]
Page
2 / 2
RF_35/0
6.10/1.0
Dieses Dokument ist urheberrec
htlich geschützt ●
T
his document
is protected by cop
yright ● Rosenbe
rger H
ochfreque
nztechnik Gmb
H
& Co. KG
10) Deburr the inner conductor with brush
and control the roundness of outer
conductor
11) Check the dimensions
Serie
X
N and 7-16
7
4.3-10
4
12) Slide back nut onto the cable until it is
completely seated. Please loose sealing
nut slightly (not complete) in order to
easily install the back nut.
13) Press clamp ring on outer conductor.
14) Expanding outer conductor on one
point with a screwdriver.
15) Insert center conductor into flaring tool´s
hole marked with ½”, start in expanded
point then press and spin the tool to
flare outer conductor.
16) Proper shape after flaring operation.
Please don´t hurt inner contact. Push
back nut until clamp ring slides into
the back nut.
17) clean the cable end with brush,
alcohol and compressed air.
18) Put connector head by hand onto the
cable and fix it with the back nut by
hand.Only turn the back nut, not the
connector head.
19) Tighten connector head and back nut
with wrenches until stop.
(Recommended torque: 18-22Nm;
Proof torque 25Nm)
20) Tighten sealing nut with wrenches
(Recommended torque: 5-8Nm;
Proof torque: 15Nm)
Link for Video:
https://
www.youtube.com/watch?v=yMMhysZPvB0
Draft
Date
Approved
Date
Rev.
Engineering change number
Name
Date
J. Gramsamer
13.08.2017
R. Fang
14.11.2018
c00
18-2094
Fl. Öllerer
14.11.2018