background image

Installation Instruction 

 

for 

½”

 annular corrugation cable 

MA_1C7-C03_U

 

 

 

Rosenberger Hochfrequenztechnik GmbH & Co. KG 
P.O.Box 1260 

D-84526 Tittmoning 

Germany 

www.rosenberger.de 

Tel. 

: +49 8684 18-0 

Email  : [email protected] 

Page 

 

2 / 2 

 

RF_35/0

6.10/1.0

 

Dieses Dokument ist urheberrec

htlich geschützt ● 

T

his document 

is protected by cop

yright ● Rosenbe

rger H

ochfreque

nztechnik Gmb

& Co. KG 

10) Deburr the inner conductor with brush 

and control the roundness of outer 
conductor 

11) Check the dimensions  

 

Serie

X

N  and   7-16

7

4.3-10

4

12)  Slide back nut onto the cable until it is 

completely seated. Please loose sealing 
nut slightly (not complete) in order to 
easily install the back nut. 

13) Press clamp ring on outer conductor. 

14) Expanding outer conductor on one 

point with a screwdriver. 

15)  Insert center conductor into flaring tool´s 

hole marked with ½”, start in expanded 
point then press and spin the tool to 
flare outer conductor. 

16) Proper shape after flaring operation. 

Please don´t hurt inner contact. Push 
back nut until clamp ring slides into 
the back nut. 

17) clean the cable end with brush, 

alcohol and compressed air. 

18) Put connector head by hand onto the 

cable and fix it with the back nut by 
hand.Only turn the back nut, not the 
connector head. 

19)  Tighten connector head and back nut 

with wrenches until stop.  
(Recommended torque: 18-22Nm; 
Proof torque 25Nm) 

20)  Tighten sealing nut with wrenches 

(Recommended torque: 5-8Nm; 
Proof torque: 15Nm) 

 

Link for Video: 

https://

www.youtube.com/watch?v=yMMhysZPvB0

 

 

Draft 

Date 

Approved 

Date 

  Rev. 

Engineering change number 

Name 

Date 

J. Gramsamer 

13.08.2017 

R. Fang 

14.11.2018   

c00 

18-2094 

Fl. Öllerer 

14.11.2018 

Отзывы: