background image

ECFanGrid

TM

 

FG-1601

Installation, Operation and Maintenance Instructions

©2017 Rosenberg Fans Canada Ltd.

ECF

AN

G

RID 

M

ODULE

 

 

ECF

AN

G

RID 

R

ETROFIT 

K

IT

ECF

AN

G

RID 

U

NO

B

OX 

A

RRAY

 

Содержание ECFanGrid FG-1601

Страница 1: ...ECFanGridTM FG 1601 Installation Operation and Maintenance Instructions 2017 Rosenberg Fans Canada Ltd ECFANGRID MODULE ECFANGRID RETROFIT KIT ECFANGRID UNOBOX ARRAY...

Страница 2: ...n 1 ECFanGrid Block Diagram Configuration 2 Safety Considerations 3 Inspection on Arrival 4 Inspection Prior to Installation 5 Installation of Modules and Unoboxes 6 Installation of Constant Volume Co...

Страница 3: ...NFIGURATION TYPICAL SYSTEM 1 1 AV 05 12 17 1 0 ROSENBERG CANADA L F ORELLANA May 12 2017 FANGRID TYPICAL CONFIGURATION BLOCK DIAGRAM Power Supplied 460V 33K 60Hz Disconnect Customer Supplied SYSTEM CO...

Страница 4: ...r if there is a discrepancy with regard to missing items the Carrier s Bill of Lading should be signed indicating damage and items missing INSPECTION prior to INSTALLATION After all forms of Packaging...

Страница 5: ...ANSA NFPA70 and or the Canadian Electrical Code CSA C22 1 The FANGRID installation must have an uninterrupted ground to minimize possible personal injury should any electrical fault occur Failure to f...

Страница 6: ...r to the FANGRID 2 Bump start the Fan s in the FANGRID to ensure Fan Rotation is correct if not check motor leads for correct connection 3 Perform start up on AC Motor s which are VFD controlled as sp...

Страница 7: ...input signal 11V input resistance 130k PWM frequency 500 Hz PWM amplitude 10V 6 10 V power supply 5 max 6mA short circuit protection 7 Analog 2 GND GND UGND PE 15V 8 0 10V PWM actual value 0 10VDC Per...

Страница 8: ...Rosenberg Fans Canada Ltd ECFanGrid Constant Volume or Constant Pressure Schematic EC FANGRID can be setup as a Constant Pressure or Constant Volume System with the combination of a Differential Pres...

Страница 9: ...ECFanGridTM FG 1601 Installation Operation and Maintenance Instructions 0 1 2 3 2 4 5 6 7...

Страница 10: ...ROTECTIVE FEATURE HAS TRIPPED Under voltage Incoming Voltage is below the tolerance limit of the specified line voltage Check main supply and fusing Failure is automatically reset after the voltage ri...

Страница 11: ...or NOT ENOUGH Air Flow RPM of Fan too low Refer to Fan does not run at max speed above Air Flow restricted Check System duct elements filtration dampers duct fittings and size Actual System pressure...

Страница 12: ...ngs Isolate Fan immediately Contact Rosenberg Support Fan operating in stall or forbidden flow region Move Operating Point by reducing pressure losses RCD Switch or Fuse tripping Ground Fault or Short...

Страница 13: ...d POWER CONTROL WIRING ARCHITECTURE MAIN POWER 460V 3 60Hz DISCONNECT WITH FUSES SYSTEM CONTROL PANEL Operating ON Alarm Main Switch 1 Main Switch 2 Enable ON OFF Cable Entry from bottom of Cabinet 46...

Отзывы: