correct direction of rotation for the consumer. An incorrect direction of rotation can
cause damage to the consumer and endanger persons.
Attempting to switch under load will cause damage to the power generating set and
the consumer.
Always reset the pole-changing switch to
clockwise after use!
4.3.2 NATO Socket (No. 5)
This is a military standard electrical socket on which the power generating set RS 9
can be started.
4.3.3 Remote monitoring Fire Can & Rosenbauer (No. 8)
Serves to start/stop the power generating set from a main control panel in/at the ve-
hicle and to via other control panels. The main switch of the power generating set is in
position ON/ON. In this position, the power generating set can be started or stopped
by using the remote start function. (Observe the operation manual for the vehicle!) It is
thus imperative to permanently connect the power generating set to a battery charger
or battery power saver. If the battery fails, the power generating set can be started at
any time using the manual recoil starter.
Note:
• The remote start function can only be guaranteed if the battery is in good working
order and sufficiently charged.
• Note that batteries can discharge autonomously!
• Observe the following if the power generating set is to be operated while fixed in the
vehicle:
› The power generating set can always be started and shut down directly at the
unit. This can even be done with a retracted folding step and the ignition or main
switch of the vehicle switched off. The power generating set will then not shut down
automatically!
› This type of operation is prohibited!
4.3.4 Insulation monitor (No. 14/ 15/ 16)
General:
The insulation monitoring component reflects increased safety requirements and
current regulations for portable power generating sets that are installed into vehicles.
Portable power generating sets with ground separation and insulation monitoring can
be operated by persons other than electricians. Suitable earthing equipment is
required. Observe mandatory distribution network lengths.
Product description:
The insulation monitoring is used in ungrounded alternating current networks. Insula-
tion monitors are designed to trigger at the thresholds defined by current regulations.
An insulation error is indicated visually and acoustically on power generating sets for
fire fighting operations. This means that the insulation error is merely shown as a
warning and the power generating set does not shut off. To allow operations to
continue the power supply to the sockets is not cut off!
Rosenbauer - Power generator RS 9