Rail Mount Transmitter with Threaded Sensor
The least complicated assembly uses:
• a threaded sensor with flying heads
• a threaded sensor connection head
• a union and nipple extension assembly
• a threaded thermowell
Refer to Volume 1 of the Rosemount Sensors Product Data Sheet
(document number 00813-0100-2654) for complete sensor and
mounting accessory information.
To complete the assembly, follow the procedure described below.
1. Attach the transmitter to a suitable rail or panel.
2. Attach the thermowell to the pipe or process container wall. Install
and tighten the thermowell before applying pressure.
3. Attach necessary extension nipples and adapters. Seal the nipple
and adapter threads with silicone tape.
4. Screw the sensor into the thermowell. Install drain seals if
required for severe environments or to satisfy code requirements.
5. Screw the connection head to the sensor.
6. Attach the sensor lead wires to the connection head terminals.
7. Attach additional sensor lead wires from the connection head to
the transmitter.
8. Attach and tighten the connection head cover. Enclosure covers
must be fully engaged to meet explosion-proof requirements.
9. Set the transmitter failure mode switch
(see Figure 2-13 on page 2-16).
10. Attach the sensor and power leads to the transmitter. Avoid
contact with leads and terminals.
Figure 2-8. Typical Rail Mount
Transmitter Mounting Configuration
Using Threaded Style Sensor
and Assembly
Rail Mount
Transmitter
Threaded
Style Sensor
Threaded
Thermowell
Standard
Extension
Threaded Sensor
Connection Head
64
4-
000
0A
04
B
Содержание FISHER-ROSEMOUNT 244EH
Страница 1: ...Models 244EH and 244ER PC Programmable Temperature Transmitters 00809 0100 4737 English Rev EA ...
Страница 8: ......
Страница 34: ......
Страница 46: ......
Страница 51: ...B 5 Figure B 1 Canadian Standards Association CSA Intrinsic Safety Installation Drawing 00644 1064 Rev AB ...
Страница 53: ...B 7 Figure B 3 Factory Mutual FM Intrinsic Safety Installation Drawing 00644 0009 Rev AA 644 0009A01A ...