![Rosemount 8712 Скачать руководство пользователя страница 174](http://html1.mh-extra.com/html/rosemount/8712/8712_reference-manual_1487460174.webp)
Reference Manual
00809-0100-4664, Rev BA
January 2010
Rosemount 8712
E-20
Model 10D1465 and
Model 10D1475 Sensors
(Integral) to 8712
Transmitter
Connect coil drive and electrode cables as shown in Figure E-18.
Figure E-18. Wiring Diagram for
Fischer and Porter Sensor
Model 10D1465 and Model
10D1475 (Integral) and
Rosemount 8712
Table E-16. Fischer and Porter Model 10D1465 and 10D1475 Sensor
Wiring Connections
Rosemount 8712
Fischer and Porter
Model 10D1465 and 10D1475 Sensors
1
MR
2
M1
3
17
3
18
1
19
2
2A
2
1
5
6
16
3
CT
M2
M1
MR
Electrode
Connections
Coil Connections
Disconnect
ROSEMOUNT 8712
TRANSMITTER
MODEL 10D1465 AND MODEL
10D1475 SENSORS
This is a pulsed DC magnetic flowmeter.
Do not connect AC power
to the sensor
or to terminals 1 and 2 of the
transmitter
, or replacement of the
electronics board will be necessary.
Содержание 8712
Страница 2: ......
Страница 4: ......
Страница 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Страница 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Страница 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Страница 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Страница 131: ...Reference Manual 00809 0100 4664 Rev BA January 2010 B 7 Rosemount 8712 Figure B 1 CSA Installation ...
Страница 132: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 B 8 Figure B 2 Factory Mutual Hazardous Locations ...
Страница 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Страница 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Страница 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Страница 211: ......