![Rosemount 5300 Series Скачать руководство пользователя страница 383](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396383.webp)
May 2016
Reference Manual
00809-0100-4530, Rev DD
369
I.4
Block Errors
lists conditions reported in the BLOCK_ERR parameter.
Table I-2. BLOCK_ERR Conditions
I.5
Modes
The AI Function Block supports three modes of operation as defined by the MODE_BLK
parameter:
Manual (Man)
The block output (OUT) may be set manually.
Automatic (Auto)
OUT reflects the analog input measurement or the simulated
value when simulation is enabled.
Out of Service (O/S)
The block is not processed. FIELD_VAL and PV are not
updated and the OUT status is set to Bad: Out of Service. The BLOCK_ERR
parameter shows Out of Service. In this mode, you can make changes to all
configurable parameters. The target mode of a block may be restricted to one or
more of the supported modes.
Condition Number Condition Name and Description
0
Other
1
Block Configuration Error:
the selected channel carries a measurement
that is incompatible with the engineering units selected in XD_SCALE, the
L_TYPE parameter is not configured, or CHANNEL = zero.
2
Link Configuration Error
3
Simulate Active:
Simulation is enabled and the block is using a simulated
value in its execution.
4
Local Override
5
Device Fault State Set
6
Device Needs Maintenance Soon
7
Input Failure/Process Variable has Bad Status:
The hardware is bad, or a
bad status is being simulated.
8
Output Failure:
The output is bad based primarily upon a bad input.
9
Memory Failure
10
Lost Static Data
11
Lost NV Data
12
Readback Check Failed
13
Device Needs Maintenance Now
14
Power Up
15
Out of Service:
The actual mode is out of service.
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...