![Rosemount 5300 Series Скачать руководство пользователя страница 242](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396242.webp)
Specifications and Reference Data
May 2016
Reference Manual
00809-0100-4530, Rev DD
228
Specifications and Reference Data
Table A-7. Remote Housing Measuring Range
Dielectric
constant
Rigid
single
8 mm
Rigid single
13 mm/
segmented
rigid single
Flexible single
Coaxial
Rigid twin
Flexible twin
1
m r
emo
te
ho
usi
n
g
Chamber /
pipe
installations <
4 in. (100 mm)
1.4
4 ft (1.25 m)
19 ft (6 m)
(1)
1. Accuracy may be affected up to + 1.2 in. (30 mm).
33 ft (10 m)
(1)(2)
2. Required chamber/pipe size is 3 or 4 in. (75 -100 mm).
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
2
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
80
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
Tank
installations
1.4
4 ft (1.25 m)
4 ft (1.25 m)
4 ft (1.25 m)
19 ft (6 m) 4 ft (1.25 m)
4 ft (1.25 m)
2
4 ft (1.25 m)
4 ft (1.25 m)
4 ft (1.25 m)
19 ft (6 m) 4 ft (1.25 m)
98 ft (30 m)
80
10 ft (3 m)
10 ft (3 m)
159 ft (48.5 m)
19 ft (6 m) 10 ft (3 m)
159 ft (48.5 m)
2
m remo
te
housi
n
g
Chamber /
pipe
installations <
4 in. (100 mm)
1.4
9 ft (2.75 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
2
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
80
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
Tank
installations
1.4
9 ft (2.75 m)
9 ft (2.75 m)
9 ft (2.75 m)
19 ft (6 m) 9 ft (2.75 m)
9 ft (2.75 m)
2
9 ft (2.75 m)
9 ft (2.75 m)
9 ft (2.75 m)
19 ft (6 m) 9 ft (2.75 m)
98 ft (30 m)
80
10 ft (3 m)
10 ft (3 m)
154 ft (47 m)
19 ft (6 m) 10 ft (3 m)
154 ft (47 m)
3
m remo
te
hous
ing
Chamber /
pipe
installations <
4 in. (100 mm)
1.4
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
2
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
80
10 ft (3 m)
19 ft (6 m)
33 ft (10 m)
19 ft (6 m) 10 ft (3 m)
33 ft (10 m)
Tank
installations
1.4
10 ft (3 m)
14 ft (4.25 m)
14 ft (4.25 m)
19 ft (6 m) 10 ft (3 m)
14 ft (4.25 m)
2
10 ft (3 m)
14 ft (4.25 m)
14 ft (4.25 m)
19 ft (6 m) 10 ft (3 m)
98 ft (30 m)
80
10 ft (3 m)
19 ft (6 m)
149 ft (45.5 m)
19 ft (6 m) 10 ft (3 m)
149 ft (45.5 m)
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...