Reference Manual
00809-0100-4027, Rev AA
December 2005
3-5
Rosemount 4500
Fast Key Sequence
The following menu indicates fast key sequences for common functions. For
full 375 Field Communicator menu tree see www.rosemount.com.
Function
HART Fast Key Sequence
Alarm Level Configuration
1, 4, 2, 7, 7
Alarm and Saturation Levels
1, 4, 2, 7
Analog Output Alarm Direction
1, 4, 2, 7, 6
Analog Output Trim
1, 2, 3, 2
Burst Mode On/Off
1, 4, 3, 3, 3
Burst Options
1, 4, 3, 3, 4
Damping
1, 3, 6
Date
1, 3, 4, 1
Descriptor
1, 3, 4, 2
Digital To Analog Trim (4-20 mA Output)
1, 2, 3, 2, 1
Field Device Information
1, 4, 4, 1
LCD Display Configuration
1, 3, 7
Loop Test
1, 2, 2
Lower Sensor Trim
1, 2, 3, 3, 2
Message
1, 3, 4, 3
Number of Requested Preambles
1, 4, 3, 3, 2
Pressure Alert Configuration
1, 4, 3, 5, 3
Poll Address
1, 4, 3, 3, 1
Poll a Multidropped Transmitter
Left Arrow, 4, 1, 1
Re-mapping
1, 4, 3, 6, 4
Rerange- Keypad Input
1, 2, 3, 1, 1
Saturation Level Configuration
1, 4, 2, 7, 8
Scaled D/A Trim (4–20 mA Output)
1, 2, 3, 2, 2
Scaled Variable Configuration
1, 4, 3, 4, 7
Self Test (Transmitter)
1, 2, 1, 1
Sensor Information
1, 4, 4, 2
Sensor Temperature
1, 1, 4
Sensor Trim
1, 2, 3, 3
Sensor Trim Points
1, 2, 3, 3, 5
Status
1, 2, 1, 2
Tag
1, 3, 1
Temperature Alert Configuration
1, 4, 3, 5, 4
Transfer Function (Setting Output Type)
1, 3, 5
Transmitter Security (Write Protect)
1, 3, 4, 5
Units (Process Variable)
1, 3, 2
Upper Sensor Trim
1, 2, 3, 3, 3
Zero Trim
1, 2, 3, 3, 1
Содержание 4500
Страница 2: ......
Страница 4: ......
Страница 66: ...Reference Manual 00809 0100 4027 Rev AA December 2005 Rosemount 4500 B 4 ...
Страница 69: ......