1.1 Preliminary Remarks

The automatic escalator deep cleaning machine 
(Rotomatic and T20) was designed and 
manufactured according to state-of-the-art 
technology and in compliance with all relevant 
regulations. This, however, does not guarantee 
that some other unavoidable dangers for 
persons and property can occur. All personnel 
working with this machine must therefore read 
and follow these operating instructions, and in 
particular, be fully trained in all of the relevant 
safe operating procedures provided by Rosemor 
International Ltd or one of its authorised 
specialists. 

These operating instructions must remain at the 
machine for use by the operator. Each operator 
must receive thorough training on handling and 
working with the machine.

1.2 Owner’s duties 

In accordance with EU directive on the use of 
operating equipment 89/655/EEC Art.6(1) and 7 
and EU framework directive 89/391/EEC Art.1(1) 
and Art. 6(1), the owner of the equipment is 
obliged to instruct all persons, particularly with 
regard to safety, who will be authorised to work 
on assembly, operation, maintenance, repair or 
dismantling of the machine.

The owner is also obliged in accordance with EU 
directive on the use of operating equipment 
89/655/EEC Art.4a to inspect the machine before 
start-up, following repair work and following 
faults or malfunction. 

1.3 Intended and specified use

The automatic escalator/travelator deep 
cleaning machine (T20) is exclusively intended 
for basic cleaning of indoor and outdoor 
escalators and travelators. Any use beyond this 
stipulation must be considered as contrary to 
the manufacturer’s intentions. The manufacturer 
will not be liable for any damage resulting from 
such work; all risk in this case will be borne 
exclusively by the operator. Correct use of the 
machine also includes compliance with the 
conditions of operation and maintenance 
stipulated by the manufacturer.

• The automatic escalator deep cleaning machine 
Rotomatic and T20 are not intended, nor suitable 
for cleaning hazardous dirt or substances. 

• The machine is not fire-proof.

• The machine is also not licensed for use in 
cleaning public streets and paths.

1.4 Who may operate the machine?

The machine may only be used by persons who 
have been trained in its operation and who are 
expressly authorised to carry out such work.
These persons should be at least 18 years old.  
All relevant accident prevention regulations and 
other generally recognised rules of safety, 
engineering, industrial medicine and the 
Highway Code must be strictly observed.
Assembly, equipment, maintenance and repair 
work demand special knowledge and may only 
be carried out by specially trained persons.

1.5 Safety for the operator

• The user must under no circumstances touch 
the plug of the power supply with damp hands.
• When the machine is being disconnected from 
the power network, only the plug itself may be 
pulled - never the power cable.
• The machine may be repaired or opened only 
by qualified personnel.
- Non-Slip safety footwear is essential when 

using this machine.

- The operator should never be allowed to 

become distracted or startled when 
operating this machine. Do not try to engage 
in conversation or attain the attention of the 
operator when they are using this machine. 

If work on the opened machine within 
connected current is absolutely 
necessary, such work may be carried out 
only by a qualified electrician who is 
familiar with all attendant dangers and 
the relevant work stipulations (VDE0100). 
When work is carried out on machine or 
parts when live, only tools specially 
intended for this purpose may be used.

Содержание T20

Страница 1: ...nual T20 Attachment Travelator Escalator Deep Cleaning Addon Rosemor International Ltd 1 Bullingdon Ave Wallingford Oxon OX10 7PL TEL 44 01491 838 011 WEB www rosemor com Email info rosemor com Designed Assembled in Oxfordshire UK ...

Страница 2: ...lator cleaning machine please see the T20i from Rosemor International The T20 is used while the escalator or travelator is moving towards you which makes it a very quick method to perform a cleaning operation Compared with its predecessor the T10 the T20 has had some important improvements implemented on it Redesigned the detergent dispensing system to provide better detergent coverage and reduce ...

Страница 3: ...lls in both handling and operating the machine and of its maintenance and care It is therefore vital that the operator receives instruction and training from either Rosemor International Ltd or one of its specialists before the cleaning machine is used for the first time This operation and maintenance manual only represent additional assistance for the operator in correct and safe use of the clean...

Страница 4: ...al safety instructions 6 1 8 Safety Instructions 6 1 9 Information on Warning Signs 6 1 10 Warning Signs Stickers 7 1 11 Product Liability 7 1 12 Emissions 7 2 Technical Data 8 2 1 Location of Components 8 2 2 1 List of Components 9 3 Operation 10 3 1 Before Starting 10 3 2 1 Preparing the Rotomatic 10 3 3 Attach T20 11 3 4 Lynch Pin 12 3 5 Connections 13 3 6 Cleaning Operation 14 3 7 Moving the T...

Страница 5: ...ot be liable for any damage resulting from such work all risk in this case will be borne exclusively by the operator Correct use of the machine also includes compliance with the conditions of operation and maintenance stipulated by the manufacturer The automatic escalator deep cleaning machine Rotomatic and T20 are not intended nor suitable for cleaning hazardous dirt or substances The machine is ...

Страница 6: ...event slip and trip hazards by cordoning off the working area and placing out adequate signage to inform any person that should enter the area of the hazards that are present such as trailing cables and slippery surfaces 1 8 Safety instructions for mains operated machines Care must be taken that the mains cable incurs no damage by being crushed torn frayed driven over etc This connection must be e...

Страница 7: ...mited to Eye protection Hand protection Foot protection Ear protection The operator is expressly notified that the machine must be used only for the intended purpose If the machine is not used for the intended purpose such use will be at the sole risk and responsibility of the user Rosemor International Ltd will not accept any liability in such cases 1 12 Emissions The A assessed equivalent contin...

Страница 8: ...2 Description 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 8 2 1 Location of Components 1 2 3 4 5 6 7 8 ...

Страница 9: ...in 3 Vacuum Outlet Connects to Rotomatic ET15B waste tank 4 Quick Release Pull Pin 5 Front Transport Wheel 6 Detergent Pipe Inlet Connects to Small Q R fitting on rear of Rotomatic ET15B 7 Motor Drive Connector Connects to T10 T20 Socket on rear of Rotomatic ET15B 8 Rear Transport Wheel 9 Guide Wheel Height Adjuster 10 Guide Wheel 11 Detergent Spray Area 12 Roller Brush 13 Vacuum Channel ...

Страница 10: ...g with the cleaning It is advised to test the operation of the T20 connected to your Rotomatic ET15B before moving into position to clean Connect the red T20 plug to the red T10 T20 outlet on the rear of your escalator cleaning machine Connect the Vacuum Hose to the T20 and the Black outlet of the Rotomatic Waste Tank or the outward facing outlet of the ET15B waste tank Connect the small detergent...

Страница 11: ...escalator travelator switched off Roll the T20 into position on the travelator escalator so that the T20 is sat just in front of the tread combs Pull the pull pin out and raise up the transit wheels to allow the T20 brushes to engage the treads Allow the pull pin to locate in the upper hole of the cam Next attach the U Bar to the T20 as shown here Note If cleaning an escalator always clean from th...

Страница 12: ...es Rosemor International Ltd 2022 12 3 4 Lynch Pin Next wheel the Rotomatic into position Now attach the U Bar to the corresponding brackets on the Rotomatic Transportation Trolley Note For ET15B separate brackets are available to attach to your older trolley ...

Страница 13: ...e tank Connect the small detergent tube from the T20 to the small Q R fitting on the Rotomatic Put the Rotomatic ET15B into Travelator Mode After these steps your setup should like this 3 Operation 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 13 Note cables and pipes have been removed for clarity Press Cleaning Mode on the Rotomatic touch screen until Travelator ...

Страница 14: ...ated by Ben Sprules Rosemor International Ltd 2022 14 When cleaning an escalator ensure there is enough flat step space for the T20 that none of the step risers can collide with the T20 3 7 Moving the T20 over Once you are satisfied with the cleaning results of the current strip you can move the T20 over to clean the next strip To do this Stop the Escalator Travelator Remove the 2x 12mm pins from ...

Страница 15: ...0 on its side unplugged as shown on pg 10 Using a scraper or similar tool remove any built up dirt and grime that may be obstructing the vacuum channel Remove any excess dirt from the brushes and white roller wheels and check everything rotates freely 3 Operation 31 3 2022 Written and illustrated by Ben Sprules Rosemor International Ltd 2022 15 The T20 will likely drip dirty water from the undersi...

Страница 16: ... Vacuum Channel Blocked A Travelator moves away from T20 A Brushes rotate in the wrong direction towards the outside of the T20 they must rotate towards the centre vacuum channel A Transit wheels have not been lifted T20 does not sit flat on the travelator see pg 9 A Vacuum hose not connected properly Q Streaks or stripes on steps after cleaning A One or more jet nozzle is blocked or obstructed A ...

Отзывы: