CRYSTALVIEW INSTALLATION AND OPERATIONS MANUAL
17
User selectable settings
(PC and SUN models)
Dipswitch SW1 on the Remote Units PCB has four switches that
allow you to change settings from their factory set values. SW1
settings only apply to the CrystalView Dual model. If your model is
a Single version, switches 1-4 should all be set to the factory
settings.
(Factory settings are in
BOLD.
)
Switch
Function
Left (OFF)
Right (ON)
1
Privacy mode
Enabled
Disables
2
Lockout time
15 sec.
2 sec.
3
Activation method
Kbd. or mouse
Keyboard
4
Scroll lock key
Normal keyboard
function
Commands to
CrystalView
Table 1. User settings (PC/SUN models)
(PC-Serial/Audio model)
The CrystalView models with the Serial/Audio option have Dipswitch
SW1 switches 1, 3, and 4 inoperable. Dipswitch 2 sets either the
right or left control key to be the key to initiate commands to the
CrystalView. (Press and release the control key, then enter the
command to send to the CrystalView.) See Figure 5 for SW1 setting
and location.
Factory settings are in
BOLD
Switch
Function
Left (OFF)
Right (ON)
1
N/A
N/A
N/A
2
Command key
Right control key
Left control key
3
N/A
N/A
N/A
4
N/A
N/A
N/A
Table 2. User settings (PC-Serial/Audio model)
(MINI model)
For normal scroll lock key operation set Dipswitch #2 on the bottom
of the Remote Unit to “ON” (default = “Off”).