background image

TENSPros

CAUTION: United States Federal Law restricts this 
device to sale by or on the order of a physician 

INSTRUCTION MANUAL

www.roscoemedical.com

Содержание Quattro 2.5

Страница 1: ...T E N S P r o s CAUTION United States Federal Law restricts this device to sale by or on the order of a physician INSTRUCTION MANUAL www roscoemedical com...

Страница 2: ...1 2 IEC60601 2 10 ISO 7010 ISO14971 ISO10993 1 ISO10993 5 ISO10993 10 Complies with MDD 93 42 EEC and Amended by directive 2007 47 EC requirements This user manual is published by Roscoe Medical Inc...

Страница 3: ...ON 4 3 INDICATIONS FOR USE 7 4 PRESENTATION 8 5 INSTALLATION 11 6 OPERATION 12 7 MAINTENANCE 36 8 TROUBLESHOOTING 37 9 SPECIFICATIONS 39 10 STORAGE 41 11 DISPOSAL 42 12 EMC TABLES 42 13 WARRANTY 46 14...

Страница 4: ...4 1 Keep yourself informed of the contraindications 2 Read understand and practice the warnings cautions and operating instructions Know the limitations and hazards associated with using any device O...

Страница 5: ...designed to be use in an MRI environment and should be removed prior to MRI exposure 8 Do not apply stimulation over the patient s neck because this could cause severe muscle spasms resulting in clos...

Страница 6: ...jury or fracture 11 Physician recommended precautions should be followed when treating patients who recently had any surgical procedures stimulation may disrupt the patient s healing process 12 Use ca...

Страница 7: ...ention or retardation of disuse atrophy 3 Increasing local blood circulation 4 Muscle re education 5 Maintaining or increasing range of motion 6 Immediate postsurgical stimulation of calf muscles to p...

Страница 8: ...and 2 During treatment press to display treatment parameters for channel 1 and 2 Rotate to adjust the output intensity for channel 2 3 Parameters Control Knob and Pause button 4 Stop Treatment Button...

Страница 9: ...on to select the parameter Time Cycle Ramp B4 Press the B4 button to select the therapeutic program Press and hold the B4 button again to save settings B5 Press the B5 button to select the parameter V...

Страница 10: ...l mode of channels 1 and 2 6 Displays treatment time cycle time or ramp time of channels 1 and 2 7 Displays 7 therapeutic waveform IF 4P IFC Interferential Traditional 4 Poles IF 2P Premodulated Tradi...

Страница 11: ...where you purchase this unit Your equipment contains the following accessories Quattro 2 5 DQ8450 1 2 5 6 7 8 9 11 3 4 Part Rubber Electrodes 2 5 X 3 5 Rubber Electrodes 2 75 x 4 3 Electrode Sponges 2...

Страница 12: ...Remove the power adapter from the wall socket Remove the power adapter from the device 6 1 2 Electrode Placement 6 OPERATION 6 1 Measures with regards to treatments 6 1 1 Electrotherapy Before the tre...

Страница 13: ...ntact with the treatment area and to give the most uniform delivery of the prescribed electrotherapy treatment Properly dispose of used electrodes upon completion of the therapy session If you are uns...

Страница 14: ...no bare metal parts of the pins exposed Securing Electrodes Remove the adhesive electrodes from the protective backing and apply to the treatment area as prescribed Ensure that the entire electrode su...

Страница 15: ...display the last treatment mode 3 Connect the electrode wires to the cable note the color of the wires and the color marks on the cable they should correspond Caution If you want to use 4 channels con...

Страница 16: ...d so when the output intensity surpasses10 0mA 10 0V and there are no electrodes placed on the patient s skin or the device is not connected to the electrodes an alarm buzzer will sound and the intens...

Страница 17: ...top the selected flashing channels not all 4 channels 14 To pause current channels treatment press the output intensity knob until desired channels either 1 and 2 or 3 and 4 flash Then press below but...

Страница 18: ...T E N S P r o s 18 Quattro 2 5 DQ8450 Symptoms Program Vector C F Beat L Beat H Time Step 1 Step 2 CC CV IFC 4P Premodulated IFC 2P Symptoms Program Vector C F Beat L Beat H Time Step 1 Step 2 CC CV...

Страница 19: ...T E N S P r o s 19 Quattro 2 5 DQ8450 Symptoms Program Freq Pulse Dur CC CV A M Time F M Burst...

Страница 20: ...T E N S P r o s 20 Russian S A Quattro 2 5 DQ8450...

Страница 21: ...the Parameters Control Knob to select the therapeutic programs from P 1 to P 10 Normal mode or from S 1 to S 10 Professional mode 6 There are two modes in the Quattro 2 5 device Normal mode and Profe...

Страница 22: ...t the vector manual parameter from 0 to 90 15 step 12 Press the Time button and then rotate the Parameters Control Knob to set the treatment time from 1min to 60min 1min step Quattro 2 5 DQ8450 Vector...

Страница 23: ...pause current channels treatment press output intensity knob until desired channels either 1 and 2 or 3 and 4 begin flashing Then press below button 17 Press the channel button or to enter channel 3 a...

Страница 24: ...to P 10 Normal mode or from S 1 to S 10 Professional mode 6 There are two modes in Quattro 2 5 Normal mode and Professional mode Switch between the two modes by pressing and holding the Step button un...

Страница 25: ...save all settings Note The settings will not be saved if you have not followed the steps above 14 For safety purposes the load detection function was designed so when the output intensity surpasses10...

Страница 26: ...or EMS A waveform Save 5 Press the Program button to choose the therapeutic program Then rotate the Parameters Control Knob to select the therapeutic programs from P 1 to P 8 Normal mode in EMS S wav...

Страница 27: ...quency from 1Hz to 250Hz 1Hz step But Freq 250 F M 8 Press the F M button and then rotate the parameters control knob to set the F M parameter from 0Hz to 249Hz 1Hz step But F M Freq 250Hz 12 Press th...

Страница 28: ...ollowed the steps above 18 For safety purposes the load detection function was designed so when the output intensity surpasses10 0mA 10 0V and there are no electrodes placed on the patient s skin or t...

Страница 29: ...ent both channels will stimulate at the same time Best used for Bi lateral conditions 2 EMS A Asynchronous stimulation For this treatment use two channels either 1 2 or 3 4 Electrodes for each channel...

Страница 30: ...P 1 to P 10 Normal mode or from S 1 to S 10 Professional mode 6 There are two modes in Quattro 2 5 Normal mode and Professional mode Switch between the two modes by pressing and holding the Step butt...

Страница 31: ...form patterns shown on page 29 20 step 13 Press the Time button and then rotate the Parameters Control Knob to set the treatment time from 1min to 60min 1min step 10 Press the Freq button and then rot...

Страница 32: ...the output intensity surpasses10 0mA 10 0V and there are no electrodes placed on the patient s skin or the device has not been connected to electrodes an alarm buzzer will sound and the intensity val...

Страница 33: ...m S 1 to S 09 Professional mode in Russian S waveform There are 1 programs P 01 or S 01 for you to select in Russian A waveform 6 There are two modes in Quattro 2 5 Normal mode and Professional mode S...

Страница 34: ...ant to save all settings Note The settings will not be saved if you have not followed the step above 10 Press the Time button and then rotate the Parameters Control Knob to set the treatment timefrom...

Страница 35: ...hannel s treatment press corresponding channel button first and then press the button This will only stop the selected flashing channels not all 4 channels 17 Press the channel button or to enter chan...

Страница 36: ...Authorized Service center Do not allow liquids to enter the ventilation holes 7 2 Cleaning the electrodes Apply the protective backing to the tacky side of the electrode before storing It may be help...

Страница 37: ...unauthorized agencies is not allowed and will terminate any claim to warranty Quattro 2 5 DQ8450 TROUBLESHOOTING For optimal use 8 Replace lead wires annually Please follow the directions on the elec...

Страница 38: ...ion the electrodes Electrodes must be a minimum of 2 inches apart Replace Replace electrodes with ones that have an active area no 2 less than 25 0cm Stimulation is ineffective Improper electrode Repo...

Страница 39: ...85 Temperature 20 C 4 F to 55 C 131 F Relative humidity 20 90 60 minutes 9 2 Waveform Specifications 4 Pole Interferential Mode Waveform Type Mode Selection Vector Carrier Frequency C F Sweep High Bea...

Страница 40: ...load 0 50V CV at 1k ohm load Treatment time 1 60 minutes TENS Mode Waveform Type Mode Selection Frequency Frequency Modulation F M Mono phasic square CC Constant Current or CV Constant Voltage 1 250...

Страница 41: ...Mode Waveform Type Mode Selection Carrier Frequency C F Burst Frequency Freq Bi phasic square CC Constant Current or CV Constant Voltage 2 5kHz 20 100 Hz Output Intensity 0 50mA CC at 1k ohm load 0 50...

Страница 42: ...e RF emissions CISPR 11 Group 1 The Quattro 2 5 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic...

Страница 43: ...lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 seconds Power frequency 50 60Hz magnetic field IEC 61000...

Страница 44: ...netic environment guidance Conducted RF lEC 61000 4 6 Radiated RF lEC 61000 4 3 Quattro 2 5 DQ8450 Portable and mobile RF Communications equipment should be used no closer to any part of the device in...

Страница 45: ...accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the Quattro...

Страница 46: ...f change within the warranty period Repairs under warranty do not extend the warranty period either for the device or for the replacement parts B The following is excluded under the warranty Any damag...

Страница 47: ...he environment and save resources and take this device to the appropriate collection points Please contact the organization which is responsible for waste disposal in your area if you have any questio...

Страница 48: ...T E N S P r o s...

Отзывы: