June 22, 2004 
 
 
 
MEMORANDUM 
 
To: 

 

Eric Tishman, Rosco Laboratories 

 
From:  

Alan Kao 

 
Subject: 

Addendum to Time-and-Distance Guidelines for Rosco Delta 3000 

 
 
In the report 

Development of Time-and-Distance Guidelines For Use Of Theatrical Smoke 

Equipment: Rosco Delta 3000

 dated May 2004 (“T&D Guideline report”), ENVIRON developed 

time-and-distance (T&D) guidelines for the use of four Rosco fog fluids in the Delta 3000 fog 
machine.  These T&D guidelines were based on release durations of 30 seconds for the 100% 
and 50% settings, and 60 seconds for the 10% setting.  This memorandum provides an 
adjustment factor (AF) for using different release durations than 30 or 60 seconds. 
 
ENVIRON conducted additional testing with the Delta 3000 fog machine to evaluate the effect 
on the T&D guidelines using different release durations.  Release durations ranging from 5 to 60 
seconds were evaluated.  Figures 1 and 2 show the percent change from the 30-second and 60-
second T&D guidelines observed at different release durations.  A linear regression was 
performed on each plot to develop the following equations for: 
 
For 100% and 50% settings: 
 

AF = (1.36 

×

 RD + 59) / 100 

 

For the 10% setting: 
 

AF = (0.93 

×

 RD + 44) / 100 

 

where: 
 
 

AF

 

= adjustment factor (unitless) 

 

RD

 

= release duration (sec)  

 

For using the Rosco Delta 3000 at release durations that differ from those on which the T&D 
Guideline report was based, the T&D guideline value from Table 2 can be multiplied by the 

 

274 Main Street  

C

  P.O. Box 1220  

C

  Groton, Massachusetts   01450  

C

  USA  

C

  (978) 448-8788  

C

  Fax: (978) 448-8825 

www.environcorp.com 

Содержание Delta 3000

Страница 1: ...TIME AND DISTANCE GUIDELINES FOR USE OF THEATRICAL SMOKE EQUIPMENT ROSCO DELTA 3000 Prepared for Rosco Laboratories Stamford Connecticut Prepared by ENVIRON International Corporation Groton Massachus...

Страница 2: ...lines 2 II TESTING METHODOLOGY 3 A Monitoring Equipment 3 B Monitoring Procedures 3 III RESULTS AND DISCUSSION 6 A Aerosol Monitor Calibration 6 B Peak Exposure Characterization 6 C How to Use the Tim...

Страница 3: ...for Rosco Stage and Studio Fluid in Delta 3000 fog machine 10 Figure 7 Guidelines for use of Rosco Clear Fog Fluid in Delta 3000 fog machine 11 Figure 8 Guidelines for use of Rosco Light Fog Fluid in...

Страница 4: ...ineral oil should be used in a manner such that an actor s exposure does not exceed a peak concentration of 25 mg m3 For chronic exposures to mineral oil the existing standards established for oil mis...

Страница 5: ...for the Delta 3000 fog machine Thus by arranging the blocking and choreography such that an actor is not situated within the restricted areas during the times specified in Table 2 and Figures 7 to 10...

Страница 6: ...he second step involves using the calibrated aerosol monitor to identify distances from the smoke release point where exceedances of the guidance levels occur These monitoring data are used to develop...

Страница 7: ...Figure 1 Rosco Delta 3000 Fog Machine ROSCO DELTA 3000 4 E N V I R O N...

Страница 8: ...ng configuration consisting of six tripod mounted aerosol monitors situated at five foot intervals from the Delta 3000 machine far left Each tripod is equipped with an aerosol monitor ROSCO DELTA 3000...

Страница 9: ...o Clear Fog Fluid 1 43 Rosco Fog Fluid 1 00 Rosco Light Fog Fluid 1 35 Rosco Delta 3000 Rosco Stage Studio Fluid 1 97 Reference ENVIRON 2002 B Peak Exposure Characterization For 100 and 50 settings mo...

Страница 10: ...he cue release an actor should not be situated within 10 to 15 feet from the front of the cue release point until at least 33 seconds following the end of the cue release It should be reiterated that...

Страница 11: ...6 ft 9 ft 10 ft 12 ft 15 ft 18 ft 20 ft 25 ft 30 ft 100 30 215 215 215 215 215 115 50 30 88 88 88 88 88 70 Rosco Clear Fog Fluid 10 60 130 130 130 130 117 73 100 30 157 157 157 87 87 87 50 30 94 94 94...

Страница 12: ...3000 Calibration factor based on slope of curve is 1 43 mg m3 glycols mg m3 aerosol Rosco Laboratories Delta 3000 Rosco Light Fluid Average PDR Concentration mg m 0 50 100 150 200 250 Total Glycol Con...

Страница 13: ...alibration factor based on slope of curve is 1 00 mg m3 glycols mg m3 aerosol Rosco Laboratories Delta 3000 Rosco Stage Studio Fluid Average PDR Concentration mg m 0 50 100 150 200 250 Total Glycol Co...

Страница 14: ...15 20 25 30 35 Time After Release sec 0 50 100 150 200 250 100 30 second release 50 30 second release 10 60 second release Figure 7 Guidelines for use of Rosco Clear Fog Fluid in Delta 3000 fog machin...

Страница 15: ...5 20 25 30 35 Time After Release sec 0 10 20 30 40 50 60 70 100 30 second release 50 30 second release 10 60 second release Figure 8 Guidelines for use of Rosco Light Fog Fluid in Delta 3000 fog machi...

Страница 16: ...0 25 30 35 Time After Release sec 0 20 40 60 80 100 120 140 160 180 100 30 second release 50 30 second release 10 60 second release Figure 9 Guidelines for use of Rosco Fog Fluid in Delta 3000 fog mac...

Страница 17: ...25 30 35 Time After Release sec 0 10 20 30 40 50 60 70 100 30 second release 50 30 second release 10 60 second release Figure 10 Guidelines for use of Rosco Stage and Studio Fog Fluid in Delta 3000 fo...

Страница 18: ...orporation ENVIRON 2001c Theatrical Haze and Fog Testing for Mamma Mia Winter Garden Theatre Prepared for Mamma Mia Broadway and Nina Lannan Associates November 12 ENVIRON International Corporation EN...

Страница 19: ...conducted additional testing with the Delta 3000 fog machine to evaluate the effect on the T D guidelines using different release durations Release durations ranging from 5 to 60 seconds were evaluate...

Страница 20: ...other than those listed in this table the equations on page 1 of this addendum can be used to calculate AF Example calculations 1 Using Rosco Fog Fluid with the Delta 3000 at a 50 setting Table 2 from...

Страница 21: ...t change in T D guidance value from 30 second value for 50 and 100 settings at release durations other than 30 seconds Figure 2 Percent change in T D guidance value from 60 second value for 10 setting...

Отзывы: