background image

10-00609   REV D 

 

 

 
 
 
 

 

 
 
 

OPERATION AND MAINTENANCE MANUAL 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

 

5618 Copley Drive 

San Diego, CA  92111-7902 

TEL: (858) 565-8500 

FAX: (858) 565-8808 

www.rosys.com

MV-LED II DC 

Содержание MV-LED II DC

Страница 1: ...10 00609 REV D OPERATION AND MAINTENANCE MANUAL 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com MV LED II DC...

Страница 2: ...1 1 DESCRIPTION 2 2 PRODUCT SPECIFICATIONS 3 2 1 GENERAL SPECIFICATIONS 3 2 2 LIGHT DISTRIBUTION 4 2 3 LIGHT OUTPUT VS DIMMING CONTROL 4 3 INSTALLATION GENERAL FUNCTIONALITY 5 4 CONNECTOR WIRING 6 5 R...

Страница 3: ...of the State of California shall govern this warranty In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS discretion the prod...

Страница 4: ...stance during installation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in you...

Страница 5: ...10 00609 REV D 1 CHANGE RECORD REV DESCRIPTION DATE A Initial release 03FEB12 B SEE EC 01134 28AUG12 C SEE EC 01333 19APR13 D SEE EC 02192 11FEB15...

Страница 6: ...6 stainless steel and titanium housing constructions Unlike conventional lamps the MV LED II uses a solid state LED light array The MV LED II is offered in 24 VDC with the option to control the light...

Страница 7: ...Temperature 10 C to 40 C Storage Temperature 25 C to 85 C depending on external connector End of Life Light Output 70 Rated Intensity 30 000 Hrs Optical Color Temperature 6300 K Nominal Lumen Output 3...

Страница 8: ...10 00609 REV D 4 2 2 Light Distribution 2 3 Light Output vs Dimming Control...

Страница 9: ...lamp draws 45 Watts typical of power at maximum light intensity Mount the lamp in any orientation using either the optional mounting clamp or your own mounting clamp The MV LED II is protected from an...

Страница 10: ...to protect the light from unintentional damage from extended use in air It is not recommended to intentionally run the light out of water for any extended period as it will reduce the product lifespan...

Страница 11: ...mp stops working please contact ROS customer service For troubleshooting see Section 7 6 Troubleshooting Problem Typical Causes Action Product won t power on Not connected properly Check cables and po...

Страница 12: ...01 Aluminum 10 00606 01 Titanium HOUSING 10 00508 01 Aluminum 10 00607 01 Titanium DRIVER 10 00562 01 ENDBELL Connector Dependant Contact Factory CONNECTOR See Connector Layout ENDBELL O RING 60 20031...

Страница 13: ...ERENCE DOCUMENTS DOC NUMBER ROS DOCUMENT DESCRIPTION 10 00234 APPLICATION NOTE INTERCONNECTING RS 485 COMPONENTS 10 00551 WIRING DIAGRAM MV LED RS485 10 00567 WIRING DIAGRAM MV LED DC 21 30022 RS 485...

Отзывы: