EN
9
9
Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when led
S1
starts to flash, or at
least once every 4 months. The Alarm signal, if it has been activated, only appears when the
Suction motor is turned on.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
• Turn the Lights and the Suction Motor off.
• Press button
T2
and hold it for
5 seconds
until the LED flashes twice in confirmation:
CHANGING
Resetting the alarm signal
• Turn the Lights and the Suction Motor off.
• Press
T3
and hold for at least 3 seconds, until LED
flashes three times in confirmation.
Changing the Filter
• Remove the Metal Grease Filter
• Remove the frame by unfastening the 4 screws (2
on the right and 2 on the left).
• Remove the saturated Activated charcoal filter,
using the hooks provided.
• Fit the new Filter, hooking it into place.
• Screw the Frame back into place using the 4 screws
removed as described above.
• Fit the Grease filter.
Lighting unit
Warning
: This appliance is fitted with a white LED lamp classed
as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001
standards; maximum optical power emitted @439nm: 7µW. Do
not look directly at the light through optical devices (binoculars,
magnifying glasses…).
• For replacement contact technical support. ("To purchase con-
tact technical support")