Page | 11
TF 200.01.0040_ENG
8.
Maintenance
8.1
Periodic maintenance of the frame
It is recommended to test the function of the frame at least once a year, for operational and safety reasons.
See 5.3.
Likewise, once a year, it
’s recommended to do a check-up of the frame by doing the following:
➢
Check that all bolt connections are fastened tightly
➢
Check that the table can move unhindered from bottom to top position. Check if the movement is
even and controlled.
➢
Check that all the cables are mounted correctly and hasn’t suffered any damage.
➢
Reset the frame
– Press the DOWN button on the control, until the table is in its bottom position. Let
go of the button and press DOWN again for 5 seconds. The legs should move below the bottom
position. This resets the control box.
8.2
Periodic maintenance of the battery
The battery isn’t maintenance-free and will discharge itself over time. For this reason, it is recommended to
recharge the battery regularly, approximately once every 14 days.
Likewise, the battery should be kept at above 25% charge, as the buzzer will go off otherwise during the
driving of the table.
In addition, the battery should be maintained at least once every 4 months, doing the following:
➢
Clean/wipe off dust from the battery
➢
Check the battery for cracks or other mechanical damage
➢
Discharge the battery fully, then recharge it to full charge. This extends the lifetime of the battery
9.
Component part list
Notice!
Ropox will make part lists available for extraordinary maintenance and repair beyond what
is described in this manual. Repair beyond what is described in this manual may only be
done by Ropox designated service personnel.
Parts included
1x Control box SMARTneo-Pro
96000545
1x Battery
96000546