10.3 Service schedule, operation and maintenance
11. Trouble shooting
11.1 The frame seems loose or unstable
➢
The screws assembling the frame have not been securely tightened.
➢
Tighten all screws, cf. mounting instructions.
11.2 The height of the frame cannot be adjusted (adjustment seems very
difficult)
➢
Check mains voltage to control unit and that the power has been switched on.
➢
Check cables and plug-in connections between control unit and motors.
➢
Check cable and plug-in connection between control unit and control switch.
➢
Check connection of cables for safety strip to control unit and safety strip.
(If no safety strip has been fitted, there must be a short-circuit plug on the safety strip
cable. See mounting instructions fig. 6.2.2).
➢
If a safety strip has been fitted:
Check that the safety strip has not been activated.
Remove the short-circuit plug from the safety strip to the Y-cable of the control unit. See
mounting instructions fig. 6.2.2). If the table works without connection of the safety strip,
the safety strip has been activated.
11.3 The frame does not move straight
➢
If the frame does not move straight, it must be
reset
, see Maintenance, section 10.2
If there has been a power failure, the table must always be reset before use.