4.4 Installation of accessories 

4.4.1 Installation of height adjustable toilet support arms 

 
 

a. attach housing to the profile with 3x M6x12 and 1x M6x16. Use a locking nut on M6x16.  

 

 

b. Mount M6 buttonhead screws on both sides. Leave about 5mm clearence between 
underside of screw head to the plastic cover.  

 

 

 

 

Содержание 40-45027

Страница 1: ...ROPOX Toilet lifter Electric User manual This manual should always be in close proximity of the product TF 200 06 0006_ENG Date 26 04 2021 ...

Страница 2: ...tion interface 9 4 1 2 Construction 10 4 1 3 mounting the product 11 4 1 4 Pair Bluetooth 14 4 2 Operating the product 20 4 3 Residual risk 20 4 4 Installation of accessories 21 4 4 1 Installation of height adjustable toilet support arms 21 4 4 2 Installation of backrest 26 5 Trouble shooting 27 6 Cleaning 27 7 Maintenance 27 7 1 Periodic maintenance 28 7 2 Calibration of actuator 28 8 Components ...

Страница 3: ...od before use and installation Always keep this manual in close proximity of the product The use installation and service of this product must be in compliance with this manual to avoid accidents and serious personal injury Never use or handle this product in other ways specified in this manual as it can result in personal safety hazards and or cause damage to the product Persons installing and or...

Страница 4: ...ance Cleaning and user maintenance shall not be made by children without supervision Do not use the product if it has defects or have become damaged before being repaired or replaced If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved The products must only ...

Страница 5: ...trically operated equipment The use of electrical height adjustable equipment can run at maximum 2 minutes followed by an 18 minute break Type B applied part The product complies with IEC 60601 1 requirements to provide protection against electric shock Consult manual for important safety related information warnings and safety precautions Class II double isolated electrical components Do not disp...

Страница 6: ...ied part MEE Class 60601 1 Class II Intended environments This product is to be used only in Proffesional Healtcare Environment Homecare Environment The device is not intended for use in special environments as defined by IEC 60601 1 2 Maximum user weight according to ISO 17966 2016 400kg Power supply 100 240V 50 60Hz I in Max 2 0A Intermittence 2min use 18min pause Height adjustment 405 655mm Spe...

Страница 7: ...l meet different sitting height needs various patient heights 3 3 Intended use The ROPOX height adjustable toilet lifter is intended to be used in both homecare and professional healthcare environments Adjusting the height will meet ergonomic demands emerging from various patient heights The toilet lifter is not intended for playing or as a training device 3 4 Intended operator The intended operat...

Страница 8: ...TF 200 06 0006_ENG 8 3 8 Product dimensions ...

Страница 9: ...TF 200 06 0006_ENG 9 4 Instructions for use 4 1 Installation of product 4 1 1 Installation interface ...

Страница 10: ...ws and rawlplugs suitable for mounting in a concrete wall The fitter should always consider the material condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type Caution Maximum pulling force per screw is 44kg at 400kg max user weight according to ISO 17966 2016 ...

Страница 11: ...3 mounting the product a Line up frame with threaded foots Mark holes 6X and drill holes for appropriate rawl plugs b Connect water hose on wall outlet and electric outlet before securing frame to the wall c Secure frame to wall ...

Страница 12: ..._ENG 12 d Mount the drain bellow as instructed below Drain finished at floor level Flex pipe is mounted on the drain adapter with a hose clamp which is then pressed into the drain Make sure the bellow is not twisted ...

Страница 13: ...TF 200 06 0006_ENG 13 Mount the bellow as shown below for correct flow ...

Страница 14: ...TF 200 06 0006_ENG 14 4 1 4 Pair Bluetooth Notification Pair the remote to the product and test full stroke before continuing installation ...

Страница 15: ...ification When pairing is complete test product stroke Make sure all cables water connection and drain connection travels freely The electrical connection shall travel unhindered and may not get intangled in other installations ...

Страница 16: ...TF 200 06 0006_ENG 16 e Cut threaded rods to length and secure them in the frame f Mount inner covers 1 and 2 2x ...

Страница 17: ...TF 200 06 0006_ENG 17 g Mount outer cover 2x ...

Страница 18: ...TF 200 06 0006_ENG 18 h Shorten Ferrule and flush pipe to length and mount them ...

Страница 19: ...9 i Mount the toilet and press pad j Finish the installation by checking 1 Rigidity test sit on the toilet and check screw connections are firm 2 Check full travel of the product goes unhindered 3 Check flushing and leaks ...

Страница 20: ...ecial care should be taken in ensuring that no children or adults are sited under the product as severer injury from entrapment may occur 4 3 Residual risk Warning Be aware that there are no persons body parts under the toilet when it is driven down as a danger of clamping may occur Caution Do not place the hand between the wall and the movable cover as a danger clamping may occur Warning In case ...

Страница 21: ...Installation of height adjustable toilet support arms a attach housing to the profile with 3x M6x12 and 1x M6x16 Use a locking nut on M6x16 b Mount M6 buttonhead screws on both sides Leave about 5mm clearence between underside of screw head to the plastic cover ...

Страница 22: ...TF 200 06 0006_ENG 22 c Slide the assembly on the two screw heads and attach the assembly with the two M6x30 as shown on the next image ...

Страница 23: ...TF 200 06 0006_ENG 23 ...

Страница 24: ...TF 200 06 0006_ENG 24 d Slide in the cover and end rubber cap ...

Страница 25: ...TF 200 06 0006_ENG 25 ...

Страница 26: ...f Ropox Back Support long is ordered together with Ropox Toilet Lifter there will be pre drilled holes in the cover cap If the back support is ordered later for subsequent mounting please see the dimension drawing for the location of holes 2 M5x16 are used ...

Страница 27: ...f with a wrung cloth Notification Do not use cleaning agents containing abrasive e g scouring powder steel wool scouring sponge This product is not designed to be sterilized Autoclaving and sterilization beyond normal cleaning as this may possibly change product safety and function Preapproved cleaning agents Tradename Solution Acticlor plus 1000ppm S90 sanirens 1 3 peracid FUTUR Alkalic 1 Solutio...

Страница 28: ...o the bottom position by pressing DOWN on the hand control until movement of both columns are in the lowest possible position 8 Components part list Notification Ropox will make parts list and circuit diagrams available for extraordinary maintenance and repair beyond what is described in this manual Repair beyond what is described in this manual may only be done by Ropox designated service personn...

Страница 29: ... is necessary this equipment and the other equipment should be observed to verify that they are operating normally 10 3 Cables Cable component Length Power cable 1 2m Hand control spiral cable Wireless Warning Use of accessories transducers and cables other than those specified or provided by the manufacturer of this could result in increased electromagnetic emissions or decreased electromagnetic ...

Страница 30: ...considered to be a contributing factor to the case and 3 The event resulted or could have resulted in one of the following outcomes death a patient a user or a third s death A serious deterioration of a patient s health a user s or third country s health status in the form of o 1 Life threatening disease o 2 lasting damage or injury o 3 Necessary medical or surgical treatment to divert life threat...

Отзывы: