Startup and operation
Version 1
RES-440
Page 27
3.
Temperature coefficient 1400ppm
(e.g. ROPEX CIRUS system)
4.
Temperature coefficient 1700ppm
(e.g. ROPEX CIRUS system)
5.
Temperature coefficient 3500ppm
(e.g. LEX3500)
6.
Temperature coefficient „variable“
Further settings in step 204.
In step 204 the temperature coefficent can be set in a range of 400…4000 ppm individually for the used heat-
sealing band then.
Step 204 in the Configuration menu is available when step 203 is set to "variable" only.
9.3.6
Configuration of the temperature range (as of software revision 100)
The temperature range can be set with steps 205 in the Configuration menu.
The setting can be 200°C, 300°C (Factory setting), 400°C or 500°C.
9.3.7
Configuration of the timer function
The necessary controller settings are explained in the detailed functional descriptions in
section 10.6 "Menu steps" on page 42 and section 10.23 "Time control (timer function)" on page 64.
They are only allowed to be entered by technically trained persons.
The timer function is activated with step 26 in the Configuration menu.
9.3.8
Relay K1 (without time control)
The function of relay K1 is specified with step 212 [29] in the Configuration menu. The following settings are pos-
sible when time control is deactivated:
1.
"Off" (Factory setting)
Relay K1 has no function
2.
"Active if Tact = Tset"
Relay K1 is activated if the actual value is inside the specified temperature tolerance band (steps 207 [24],
208 [25]). If the actual temperature is outside the tolerance band, relay K1 is deactivated (see graph below).
!
!
Set
Output
Set+
Δϑ
lower
Set+
Δϑ
upper
Actual value
Time
Time
open
closed
Relay K1