![Ropex RESISTRON RES-440 Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/ropex/resistron-res-440/resistron-res-440_operating-instructions-manual_1486111042.webp)
Controller functions
Page 42
RES-440
Version 1
10.6
Menu steps
No.
Name
Description
Setting range
Home position
The specified set value and the current actual value
are displayed in digital form. The actual value is also
represented as a dynamic bar.
If time control (step 209 [26]) is active, the heat-
sealing time and the cooling value are also dis-
played.
The heatsealing band can be heated manually (to
the specified heatsealing temperature) by pressing
the "HAND" key.
101
[1]
Heatsealing
temperature
The required heatsealing temperature (set point)
can be set with the "UP" and "DOWN" keys. The
maximum selectable set point can be limited with
step 203 [22] (alloy/range) and step 204 [23] (max.
temperature). The set point is indicated in the home
position.
Depends on setting of
step 205 [22]:
0, 40°C…maximum tem-
perature (step 206 [23])
102
[2]
Preheating temper-
ature
The required preheating temperature can be set
with the "UP" and "DOWN" keys. The maximum
temperature (step 206 [23]) applies to both the
heatsealing temperature and the preheating tem-
perature.
The preheating function can be deactivated by
entering 0°C.
Depends on setting of
step 205 [22]:
0, 40°C…maximum tem-
perature (step 206 [23])
103
[3]
Starting delay
This option allows the heatsealing time to be
preceded by a starting delay. This delay time begins
as soon as the start signal is applied. When it
elapses, the heatsealing time is activated.
This function can only be selected if time control
(step 209 [26]) is active.
0…9.9s
104
[4]
Heatsealing time
The length of the heatsealing pulse can be set with
the "UP" and "DOWN" keys. The specified heat-
sealing time is indicated in the home position.
This function can only be selected if time control
(step 209 [26]) is active.
0…99.9s, EXT