Startup and operation
Page 24
RES-409
Version 1
on page 50). CAN message address 8 must contain the value 10 (dec) for this purpose (
see section 10.3
"Receiving CAN messages" on page 32).
9.2.3
Configuration of the fault relay
If the jumper is not inserted, the fault relay is permanently energized (fault contact between
terminals 13 and 14 closed). The other controller functions (e.g. heatsealing band heating,
AUTOCAL etc.) are not affected.
If the "Fault output deenergized at fault/PC CONFIGURATION" position is selected (as of February 2007), the
behavior of the fault output can be configured more finely in the ROPEX visualization software (
see
section 10.12 "Diagnostic interface / visualization software (as of February 2007)" on page 50).
9.2.4
Configuration of the CAN interface
The CAN interface of the RES-409 is configured with DIP switches. The baud rate and some of the identifiers can
be set. It is also possible to activate a terminating resistance.
The CAN BUS-interface of the RES-409 supports CAN 2.0A according ISO 11898. CANopen is not
supported.
All controllers manufactured as of February 2007:
0
5
1
2
3
4
6
7
8
9
Alarm relay de-
energized by alarm/
PC-CONFIGURATION.
Alarm relay energized
by alarm.
(factory setting)
CONFIGURATION
ALARM OUTPUT
DE-ENERGIZED / PC
AT ALARM
ENERGIZED
!
!
Controller housing
Factory settings
3
3
2
2
1
1
4
4
5 6 7 8
ON
ON
OFF
OFF
T
E
R
M
IN
A
T
IO
N
ID
E
N
TI
FI
E
R
SE
E
M
ANU
AL
BAUDRA
T
E
SEE
M
ANUAL
ON
O
N
ON
12
3
4
56
78
12
34
OF
F