Controller functions
Version 1
RES-407
Page 25
7.3
Temperature indication (actual value output)
The RES-407 supplies an analog 0…10VDC signal, which is proportional to the real ACTUAL temperature, at ter-
minals 17+14.
Voltage values:
0VDC
0°C
10VDC
300°C (ATR-3) or 500°C (ATR-5)
(depending on the contr. configuration)
The relationship between the change in the output voltage and the ACTUAL temperature is linear.
RES-407
17
max. 5mA
14
GND
33ohms
Actual value
output
0…10VDC
-
+
0…10VDC
Temperature
meter
e.g. ATR-x
+
13
0 - 300°C range
1
2
3
4
5
6
7
8
9 10
300
Te
m
p
er
a
tu
re
T
°C
20°C
"ZERO"
VDC
Voltage U
60
90
120
150
180
210
240
270
0.66V