![Roper Whitney 10M14-H Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/roper-whitney/10m14-h/10m14-h_operation-manual_1486062009.webp)
ELECTRICAL CONNECTIONS
WARNING:
Electrical Danger -- Misuse or improper installation of machinery connected to
a source of electricity may result in accidental shock that could cause injury or
death. Installation must conform to National Electric Code (Article 250) --
Grounding, etc.
Electrical connections must be made by a trained and qualified electrician.
Electrical characteristics shown on motor plate and control panel must match the
power source; and all electrically powered equipment must be grounded.
A fusible electric "disconnect" panel box must be installed for the line incoming
three-phase electrical power.
CAUTION:
Motor direction must match the motor
arrow. See Figure 1, below. Switch any two single-phase leads to reverse the
motor rotation --
WARNING:
Incoming three-phase electrical power must be
turned off at the fusible "disconnect" panel box before reversing leads to reverse
the motor direction.
Figure 1
MAINTENANCE
The 10M14-H shear requires a minimum maintenance schedule. The rotating
bearings are self-lubricating and require no maintenance. These are the bearings
associated with the mechanical linkage pin connections, and the bearings between
the actuator shaft and legs. The ram gib-guide bearings are made from bearing
bronze, and have grease-pockets packed with bearing grease at the Factory. These
are long-life bearings; however, if a problem occurs consult the Roper Whitney of
Rockford, Service Department. The motor gear-box is grease packed and requires
no maintenance.
CAUTION:
The backgauge mechanism will require periodic oiling with standard
machine lubricating oil, as needed, to insure smooth actuating.
7
Содержание 10M14-H
Страница 5: ...3 ...
Страница 13: ...11 ...
Страница 14: ...Figure 2 12 ...
Страница 17: ...5 4 2 1 3 Figure 3a ADJUSTMENT NUT Figure 3b 15 ...
Страница 30: ...APPENDIX 10M14 H PHYSICAL DIMENSIONS FIGURE 1 ...
Страница 32: ...230V STD ELECTRICAL WIRING DIAGRAM FIGURE 3A ...
Страница 33: ...230V STD ELECTRICAL PANEL LAYOUT FIGURE 3B ...
Страница 34: ...230V DRO ELECTRICAL WIRING DIAGRAM FIGURE 4A ...
Страница 35: ...230V DRO ELECTRICAL PANEL LAYOUT FIGURE 4B ...
Страница 36: ......
Страница 37: ...6M14 10M14 AIR OPERATED FRONT MATERIAL RETURN OPERATIONS MANUAL ver 1 0 10 9 00 ROPER WHITNEY OF ROCKFORD INC ...
Страница 38: ......
Страница 60: ...6M14 10M14 Air Operated Front Material Return Page 21 Electrical Diagram ...
Страница 61: ...6M14 10M14 Air Operated Front Material Return Page 22 Air Circuit Diagram ...
Страница 62: ...NOTES Copyright 1999 Roper Whitney of Rockford Inc 2833 Huffman Blvd Rockford Illinois 61103 ...
Страница 65: ...SECTION 1 BASIC MECHANICAL ...
Страница 66: ...1 3 4 5 6 7 8 9 10 11 12 13 11 10 9 1 1 8 7 4 5 15 6 14 3 2 FIG 1 BASIC MECHANICAL 10M14 16 ...
Страница 68: ...1 2 7 6 8 5 4 3 FIG 2 BASIC MECHANICAL 10M14 ...
Страница 70: ...1 5 1 2 8 11 10 9 3 4 3 6 7 2 FIG 3 BASIC MECHANICAL 10M14 ...
Страница 74: ...1 2 3 4 8 7 9 10 5 11 7 13 1 14 4 2 1 14 4 3 2 1 10 9 15 12 2 4 4 FIG 5 BASIC MECHANICAL 10M14 ...
Страница 76: ...3 1 2 4 9 5 6 8 7 10 14 11 12 13 6 FIG 6 BASIC MECHANICAL 10M14 ...
Страница 78: ...11 2 10 1 2 9 1 5 4 3 7 1 2 2 8 1 1 6 2 FIG 7 BASIC MECHANICAL 10M14 ...
Страница 80: ...1 2 3 4 5 6 7 24 22 23 25 26 20 18 16 8 9 15 10 11 12 13 14 17 13 19 FIG 8 BASIC MECHANICAL 10M14 ...
Страница 82: ......
Страница 83: ...SECTION 2 ELECTRICAL AND CONTROLS ...
Страница 84: ...FIG 1 ELECTRICAL AND CONTROLS 10M14 ...
Страница 86: ...FIG 2 ELECTRICAL AND CONTROLS 10M14 ...
Страница 88: ...FIG 3 ELECTRICAL AND CONTROLS 10M14 ...
Страница 90: ...1 2 3 4 5 13 7 12 11 10 9 6a 6 7 6a 8 FIG 4 ELECTRICAL AND CONTROLS 10M14 ...
Страница 92: ......
Страница 93: ...SECTION 3 BACKGAUGE AND MATERIAL RETURN ...
Страница 98: ...FIG 3 BACKGAUGE AND RETURN 10M14 ...
Страница 102: ...FIG 5 BACKGAUGE AND RETURN 10M14 ...
Страница 104: ...1 2 3 4 FIG 6 BACKGAUGE AND RETURN 10M14 ...