Installation Instructions for Hyper LED Mirror

RR.KH.LEDM.06.10

Roper Rhodes Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF    

|

    Tel: 01225 334148    

|

    waww.roperrhodes.co.uk

Please read carefully before you start and retain for future reference

Heated pad power 

connector

4x wall plugs

4x screws

1

4

The wall surface must be of suitable strength and construction. 

NOTE:  Wall plugs provided are suitable for Stone or Brick walls.  For other wall types use 
appropriate wall plugs.  If in doubt consult an expert.

To ensure correct operation of the infrared sensor the mirror must be mounted so that 
there is a minimum of 150mm clearance immediately adjacent to the sensor.  Where this is 
not possible the sensor can be relocated by drilling a 12mm hole in the mirror body (not 
glass) in the desired location, unscrewing the plastic nut from the sensor (see diagram 3) 
and reinstalling it in the new hole.  The old hole must be blocked using the spare grommet 
supplied.  

1)  Carefully remove the mirror by unfastening the securing screws on the sides of the 
mirror and separate from the main body.  Place the mirror, screws and washers in a safe 
place for now. The heated mirror pad and the LED light strips should be disconnected by 
separating the plugs.  

2)  Mark the desired height of the mirror and draw a horizontal line on the wall (using a 
spirit level) which corresponds with the height of the top holes in the back of the mirror 
body.  

! IF IN DOUBT CONSULT YOUR ELECTRICIAN !

IMPORTANT:  Loose connections can lead to over heating.  Excessive temperatures may 
lead to scorching of the plastic components, and in extreme cases may even melt.  
Charring of components is always a consequence of faulty installation or maintenance, 
and any claims are excluded from the warranty.

4)  Reconnect the heated mirror pad and the LED light strips.

5)  Replace the mirror over the front of the body, aligning the holes in the brackets with the 
screw holes.  Make sure that the glass fits completely flat on the face of the body.  Secure 
with the screws and washers removed in stage 1.

6)  Turn back on the electrical supply so that your LED mirror is operational.

7)  To switch the mirror on or off move your hand past the Infrared sensor (must be within 
6cm), the heated pad is turned on when the LED lights are illuminated.  We recommend the 
product is turned off after use.

Strip wires to a suitable

length.  DO NOT connect

to a plug & socket outlet.

Colour Coding:

L    - Live 

= Brown

N   - Neutral = Blue

      - Earth  = Green & Yellow

PROCEDURE

Holding the mirror body in place on the horizontal line, mark off all 4 holes in the back of 
the mirror body.  Also mark off where the electrical supply cable must be placed in case 
this needs to be chased out locally for the installation.  Place the mirror body to one side 
and drill the holes as necessary for the wall plugs.  Insert the wall plugs and screw the 
mirror body in position having fed the power supply cable through the rubber grommet in 
the mirror body.  Make sure that all screws are secure.

3)  Ensure that the electrical supply is turned off at the mains.  Remove the connection box 
cover inside the mirror body and the cable clamp to allow the electrical connections to be 
made as follows:

 

THIS PRODUCT IS MANUFACTURED TO CLASS I

CATEGORY AND MUST HAVE AN EARTH CONNECTION.

Strip the mains PVC supply cable as necessary.  Thread the power supply through the 
rubber grommet on the switch box and make the necessary connections in accordance 
with the current IEE Regulations.  Firmly tighten all terminal connections.  Make sure the 
cable clamp is replaced and tightened and the connection box cover is securely screwed 
back on.

Parts Inluded

1x grommet

1x mirror

LED power connector

Mirror glass

Cable clamp

Connection box cover & screw

Power supply cable

Body

3

2

N.B. Ensure connection box cover is securely fastened

in place after connections have been made

L

N

Output Wires

Live Terminal

Connection

Earth Terminal 

Connection

Neutral Terminal 

Connection

Cable Clamp

To remove and relocate sensor

(if required) 

IR Sensor switch 

Shaver transformer

Shaver socket

The shaver socket is always active & 

able to charge whether light is on/off

Plastic nut

Infrared sensor

Shaver socket