![Roper Rhodes Hyper MLE370 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/roper-rhodes/hyper-mle370/hyper-mle370_installation-instructions_1486023002.webp)
Installation Instructions for Hyper LED Mirror
RR.KH.LEDM.06.10
Roper Rhodes Ltd, Brassmill Lane Trading Estate, Bath, BA1 3JF
|
Tel: 01225 334148
|
waww.roperrhodes.co.uk
Please read carefully before you start and retain for future reference
Heated pad power
connector
4x wall plugs
4x screws
1
4
The wall surface must be of suitable strength and construction.
NOTE: Wall plugs provided are suitable for Stone or Brick walls. For other wall types use
appropriate wall plugs. If in doubt consult an expert.
To ensure correct operation of the infrared sensor the mirror must be mounted so that
there is a minimum of 150mm clearance immediately adjacent to the sensor. Where this is
not possible the sensor can be relocated by drilling a 12mm hole in the mirror body (not
glass) in the desired location, unscrewing the plastic nut from the sensor (see diagram 3)
and reinstalling it in the new hole. The old hole must be blocked using the spare grommet
supplied.
1) Carefully remove the mirror by unfastening the securing screws on the sides of the
mirror and separate from the main body. Place the mirror, screws and washers in a safe
place for now. The heated mirror pad and the LED light strips should be disconnected by
separating the plugs.
2) Mark the desired height of the mirror and draw a horizontal line on the wall (using a
spirit level) which corresponds with the height of the top holes in the back of the mirror
body.
! IF IN DOUBT CONSULT YOUR ELECTRICIAN !
IMPORTANT: Loose connections can lead to over heating. Excessive temperatures may
lead to scorching of the plastic components, and in extreme cases may even melt.
Charring of components is always a consequence of faulty installation or maintenance,
and any claims are excluded from the warranty.
4) Reconnect the heated mirror pad and the LED light strips.
5) Replace the mirror over the front of the body, aligning the holes in the brackets with the
screw holes. Make sure that the glass fits completely flat on the face of the body. Secure
with the screws and washers removed in stage 1.
6) Turn back on the electrical supply so that your LED mirror is operational.
7) To switch the mirror on or off move your hand past the Infrared sensor (must be within
6cm), the heated pad is turned on when the LED lights are illuminated. We recommend the
product is turned off after use.
Strip wires to a suitable
length. DO NOT connect
to a plug & socket outlet.
Colour Coding:
L - Live
= Brown
N - Neutral = Blue
- Earth = Green & Yellow
PROCEDURE
Holding the mirror body in place on the horizontal line, mark off all 4 holes in the back of
the mirror body. Also mark off where the electrical supply cable must be placed in case
this needs to be chased out locally for the installation. Place the mirror body to one side
and drill the holes as necessary for the wall plugs. Insert the wall plugs and screw the
mirror body in position having fed the power supply cable through the rubber grommet in
the mirror body. Make sure that all screws are secure.
3) Ensure that the electrical supply is turned off at the mains. Remove the connection box
cover inside the mirror body and the cable clamp to allow the electrical connections to be
made as follows:
THIS PRODUCT IS MANUFACTURED TO CLASS I
CATEGORY AND MUST HAVE AN EARTH CONNECTION.
Strip the mains PVC supply cable as necessary. Thread the power supply through the
rubber grommet on the switch box and make the necessary connections in accordance
with the current IEE Regulations. Firmly tighten all terminal connections. Make sure the
cable clamp is replaced and tightened and the connection box cover is securely screwed
back on.
Parts Inluded
1x grommet
1x mirror
LED power connector
Mirror glass
Cable clamp
Connection box cover & screw
Power supply cable
Body
3
2
N.B. Ensure connection box cover is securely fastened
in place after connections have been made
L
N
Output Wires
Live Terminal
Connection
Earth Terminal
Connection
Neutral Terminal
Connection
Cable Clamp
To remove and relocate sensor
(if required)
IR Sensor switch
Shaver transformer
Shaver socket
The shaver socket is always active &
able to charge whether light is on/off
Plastic nut
Infrared sensor
Shaver socket