Henley Basin Mixer
Installation & aftercare instructions
Please retain for future reference
Product code
T261102
ADJUSTING CERAMIC INDICES
To adjust the alignment of the ceramic indices, first
unscrew the bezel and ceramic indices assembly from
the tap handle.
The ceramic indices are held in place by a threaded brass
plate. Loosen the brass plate with a No. 16 Hex (Allen)
Key, but do not remove from bezel.
Rotate the ceramic indices until the printed logo is at the
desired position. You may need to screw the bezel and
indices assembly back onto the handle body to check
alignment and adjust as necessary.
When you are happy with the position, re-tighten the
brass plate , making sure to hold the ceramic indices still.
No. 16
Hex Key
Brass Plate
Ceramic Indices
Bezel
ADJUSTING HANDLE ALIGNMENT
To adjust the alignment of the handle in
relation to the body, unscrew the bezel and
ceramic indices from the top of the handle.
Unscrew the spindle bolt, and set aside
with the spindle bolt washer.
Lift the handle off the spindle and replace at
the desired angle using the micro
adjustment teeth.
Re-attach the washer and spindle bolt and
tighten.
Screw the bezel and ceramic indices
assembly back onto the handle body.
Bezel and Ceramic
indices assembly
Spindle Bolt
Washer
Spindle
Handle Body
Micro Adjust
teeth
Handle and Indices Adjustment: