ROPE INNOVATION CO., LTD.
CONFIDENTIAL NO.
:
ROPE-15121802
Copyright © 2017 ROPE INNOVATION CO., LTD. All rights reserved. Website:
12
Set GPS location
uploading interval
time
Interval,x,passwo
rd
Eg
:
Interval,30,123456
Interval time is 30s
by defualt setting ,
setting GPRS Time is
30s
Enable monitoring
limited, only 3
service numbers
can monitor track
LisLimit,ON,pass
word
LisLimit,ON,123456
Config OK/Config
failed
Disable the limited
of only service
number can
monitor
LisLimit,OFF,pas
sword
LisLimit,OFF,123456
Factory default status
is disable limited
Active sleep mode
Sleep
mode,x,123456
Sleep mode,0,123456
X=0 non-sleep-mode, upload data by interval time
X=1 not detect shake in 5minutes ,device will into
sleep mode,if detect shake,it will upload data
immediately , and upload data by interval time in
moving status .at the same time in sleep mode
status can use any SMS or calls to awake tracker
X=2 If the tracker sleeps as the time interval set by
Timing Command, then it will upload location data
as the time interval set by Interval Command
regardless of moving or not in 5 minutes after
which the sleeping mode ends.
During the sleeping ,the tracker will not give
reaction to all commands from plarform;and the
sms commands sent by user will be replied only
after the tracker is awake.
During 5 min after waking up,the tracker can reply
to the sms commands and operation in platform can
get response too.
Config OK/Config
failed
Geo-fence alarm
setting
geo-fence,lati,lon
gti,radius,in,out,
password
Eg:
geo-fence,22.58699,113.91573,1000,1,1,
123456
Lati=[-90.000000----90.000000]
Unit= degree
Positive= N
Negative=S
Longti=[-180.000000----180.000000]
Unit= degree
Positive=E
Negative=W
Radius =[1-65536]
Unit = M radius
Config OK/Config
failed