background image

24

100 HD

MAINTENANCE

TIGHTNESS CHECK

ELECTRICAL MAINTENANCE

The DOL starter is located on the right side of the machine. In an 
event  of  the  machine  ge ng  tripped,  the  DOL  starter  
automa cally resets. 
Wait for 30 seconds before restar ng the machine.

NOTE: Before leaving or servicing the machine, park on 
a level surface, turn off mains and unplug power cord.

IMPORTANT:  All  electrical  repairs  should  be  done  by 
authorized Roots Mul clean Ltd. service engineer 

ONLY

.

Hoses:

Ensure  that  the  connec ng  hoses  are  in  good  opera ng 
condi on.
If  the  hoses  are  damages,  cracked  or  broken,  they  must  be 
replaced.
Check inlet hoses for clogging.
To clean the hoses, scrape the inlet from the outside to remove 
any deposits.

Gasket:

Check the condi on of the top cover gasket for wear or damage, 
replace if required.
Check the condi on of the suc on gasket for wear or damage, 
replace if required.

STORING THE MACHINE

The following steps should be taken when storing 
the machine for an extended period of  me.

Ÿ

Disconnect power cord from mains.

Ÿ

All hoses and tools have to be removed from the machine and 
stored in a safe dry place.

Ÿ

Empty the collec on tank dry/wet.

Ÿ

Store the machine in a dry indoor area.

Ÿ

Close the suc on port with a cap.

Ÿ

Lock the castor wheel.

NOTE: Do not expose the machine to 
rain. Store indoors only.

NOTE: To prevent poten al damage 
to the machine store the machine in a 
insect and rodent free environment.

If there should be repeated cases of failure, look for reason.

NOTE

DOL Starter

CLEANING THE MACHINE

=

Unplug power cord from wall socket.

=

Lock castor wheel.

=

Empty dry collection tank and clean.

=

Drain and clean wet collection tank.

=

Use  a  damp  sponge  with  mild  detergent  to  clean  the 
exteriors of the machine.

=

Ensure that water does not enter any electrical part.

=

DO NOT use high pressure jet or steam cleaning equipments 
to clean the machine.

DO  NOT  CLEAN  THE  MACHINE  BY  MEANS  OF 
VAPOUR  JET  OR  HIGH  PRESSURE  CLEANING 
EQUIPMENT.

WARNING

WARNING: Disconnect power cord.

Содержание 100 HD

Страница 1: ...1 100 HD Operator s Manual 100 HD Industrial Vacuum Cleaner Wet Dry Electric Read this manual completely and understand the instructionsbeforeoperatingthemachine EnglishVersion...

Страница 2: ...2 100 HD...

Страница 3: ...tsMulticleanLtd R K G IndustrialEstate Ganapathy Coimbatore 641006 India MACHINE DATA Please fill at the time of installation for future reference Model No _______________________________ Serial No __...

Страница 4: ...air or maintenance work to be performed please ensure that you get the machine serviced from an authorised service center or dealer of RMCL to ensure thatthewarrantyisnotvoid ACCEPTANCEOFTHEMACHINE On...

Страница 5: ...or example in hospitals factories rental businesses It is designed to clean and collect solid liquid non flammable materials in an indoor environment Useonlyrecommendedfilters accessories Do not use t...

Страница 6: ...m3 h 530 530 Filter Surface Area cm2 30 000 30 000 Theoritical Capacity Dry Liters 100 100 Suction Inlet Dia mm 50 50 Filter Type STAR STAR Sound Level dB A 82 82 Protection IP 55 55 Insulation Class...

Страница 7: ...h 530 530 Filter Surface Area cm 2 30 000 30 000 Theoritical Capacity Dry Liters 100 100 Theoritical Capacity Wet Liters 65 65 Suction Inlet Dia mm 50 50 Filter Type STAR STAR Sound Level dB A 82 82...

Страница 8: ...rationofthemachine Lostorillegiblestickersmustbereplacedattheearliest Prior to operation of the machine the operator must ensure that the machine and its working implements are in proper andsafeoperat...

Страница 9: ...ged contact with solvents and inhaling their vapors Avoidclosetoopenflamesorsourcesofheat Neverusethemachinewithoutthefilter Do not vacuum lit cigarette ends The filter could be damaged Make sure all...

Страница 10: ...cord is not damaged by running over squeezing dragging etc The power cords must be checked regularly with regard to damageandaging The machine must not be used unless the power cord is in propercondi...

Страница 11: ...entdamagetoitswheels Tomovethemachineusethelargehandle c For greater convenience the most frequently used accessoriescanbeplacedintheaccessorytray d ENVIRONMENTAL RESPONSIBILITY Thepackagingmaterialca...

Страница 12: ...e Operator s Manual ToxicHazard NoSmoking ElectricalHazard DisconnectPowercord Do not let powercord come in contact with water or other fluids ElectricShockHazard Do Not Use High Pressure Jets General...

Страница 13: ...2 Top cover 3 Latch 4 Vacuum hose 5 Dry collection tank 6 On Off switch 7 Vacuum gauge 8 Power cord 9 Side channel blower 10 Swivel wheel with lock 11 Filter shaker lever 12 Extension pipe 2 nos 13 F...

Страница 14: ...9 On Off switch 10 Vacuum gauge 11 Power cord 12 Side channel blower 13 Mechanical float 14 Fluid drain valve 15 Swivel wheel with lock 16 Filter shaker lever 17 Extension pipe 2 nos 18 Flexible hose...

Страница 15: ...ker 1 Warning Sticker 2 Filter Shaker Sticker KNOW YOUR MACHINE MACHINE ORIENTATION Front Rear Right Left WARNING DO NOT VACUUM FLAMMABLE LIQUIDS DO NOT VACUUM EXPLOSIVE OR FLAMMABLE DUST WARNING SHAK...

Страница 16: ...The machine is shipped in a packed condition to the customer s place To unpack the machine followthebelowsteps Removethepackingcratesfromthesidesandtop Removetheboxcontainingtheaccessories RemoveJ Bol...

Страница 17: ...uld comply with its procedures If any part of the opera on and safe use of this equipment is not completely understood consult an authorized dealer for a complete explana on If the operator cannot rea...

Страница 18: ...c accessories withthemachinealso Ensure that there are no ammable materials in the vicinity of themachineduringvacuuming Worksite Start Up Test By iden fying any problem before traveling to the worksi...

Страница 19: ...haker wait for a few seconds before removing the collection tank from the machine to preventflyingofdust Note If the machine does not vacuum any material the collection tank must be full Empty the col...

Страница 20: ...thefluiddrainvalve i inthecollectiontankcompletely Turnonmainspower Pressthestartbutton green j tostartthemachine Startvacuuming Check the vacuum gauge k periodically to ensure proper performanceofthe...

Страница 21: ...artingthemachine Note Machine does not restart automatically after an TOP event It hastobestartedmanually The machine is equipped with a wet float system to prevent excess liquid entering to the filte...

Страница 22: ...ld not be done by hand but using appropriatetoolsorequipment l Maintenance and repair work may be carried out only by means of suitable tools and by the people trained in the factory For reasons of sa...

Страница 23: ...ilter h Replace the clean filter or a new filter and follow the procedureinvice versatocompletetheprocedure Beforeremovingthefilterfromthemachine lockcastorwheel All the material trapped by the filter...

Страница 24: ...mage replaceifrequired STORING THE MACHINE The following steps should be taken when storing themachineforanextendedperiodof me Disconnectpowercordfrommains Allhosesandtoolshavetoberemovedfromthemachin...

Страница 25: ...lace Collection tank is full Empty tank Filter blocked Replace filter Seals worn Clean the seals is necessary replace them Air leak Check for leaks in the hose clamps tighten if necessary Machine fail...

Страница 26: ...mber Checktheimpellerexhaustpipetopreventanyblockage Liquidslikewater coolantwithmetalchipscanbeextracted wetversiononly Usetheappropriateportforwetapplication Useonlywettoolforwetapplication Donotuse...

Страница 27: ...27 100 HD...

Страница 28: ...28 100 HD Roots Multiclean Ltd R K G Industrial Estate Ganapathy Coimbatore 641 006 India Phone 91 422 4330 330 E mail rmclsales rootsemail com Web rootsmulticlean com Toll Free 1800 41 99 77 9...

Отзывы: