Accura 2300/2350 User Guide
Chapter 4 Accura 2300 Operation/Setup
ⓒ
2011 Rootech Inc. All Rights Reserved
Page 127
Chapter 4 Accura 2300 Operation/Setup
Front of Accura 2300 comprises 5.2” LCD, which displays measurement information and setup, 4 LEDs which
display power supply and communication status and 4 buttons for selection of all operation states.
Device Configuration
Fig 4.1 Accura 2300 Front configuration
Operation Mode
Accura 23000 operates in 3 modes as follows.
Mode
Function
Display mode
Selectively displays measurements of the selected Accura 2350 Module ID.
Setup mode
Confirms and changes the configured value of measurement and operation factors[connection, PT,
event, Ethernet communication, RS-485 communication, etc.].
Event log mode
Displays event logs of power quality such as dip and swell event logs.
LED Display
4 LEDs placed at the lower-left part display the operation states of Accura 2300.
LED Name
Color
Function
POWER
GREEN
On, when the status of inner power supply of Accura 2300 is normal.
EVENT
RED
Blink, when start event such as Dip/Swell generates.
ETHERNET
YELLOW
Blink, during Ethernet communication.
MODULE
YELLOW
Blink, during RS-485 communication with Accura 2350.
Button Operation
Front buttons comprise 4 buttons, Left[
<
]/ESC, Up[
^
]/SETUP, Down[
v
]/EVENT, and Right[
>
]/ENTER. In case
of short press, Left[
<
], Up[
^
], Down[
v
], and Right[
>
] buttons operate as direction moving function. In case
of long press, pressing the buttons for more than 1-second, buttons operate as special functions, ESC, SETUP,
EVENT, and ENTER.