![Room&Board 1111LP-TGR Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/roomandboard/1111lp-tgr/1111lp-tgr_owners-manual_1485402014.webp)
14
TIPS & TROUBLESHOOTING
If the fire table will not ignite or stay lit
Make sure that the LP tank has gas in it and that the connection between the hose and the
tank is secure and threads on tank and regulator are properly aligned. Verify that the valve
key is not stripped out and that the valve is opening/ closing.
Other Common Problems
Clogged or Obstructed Burner
It is common for bugs, especially spiders, to make webs or nests inside of burner tubes. If it seems
like you are getting low or no gas flow, visually check all openings in the burner for signs of clogs. If
you see anything clogging the burner try using compressed air to remove the debris.
Out of Gas
Be sure that your tank is not empty. Low tanks can result in lower flames.
Cold Temperatures
Cold temperatures outside may result in lower tank pressures causing the flames to be lower. Do not
use your fire table in extreme temperature conditions. Allow the temperature of your tank to rise
and as the pressure in the tank increases the flame size will increase. NEVER heat your tank; allow it
to warm up naturally.
High Winds
High winds may cause the flame to blow out. Do not operate your fire table in high wind conditions.
If you continue to have problems with your fire table please
contact Real Flame customer service at : 1-800-654-1704