650 nanometers.
- The total continuous output of the beams never exceeds 1.0mW.
- Product complies with EMC Test according to EN61000-6-
3:2001+A11:2004,
EN61000-6-1:2001, EN61326-1:2013, IEC 61326:2012 and FCC Test 
according to PART 15.

BLUETOOTH SAFETY 

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause 
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning 
the equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna. Increase the separation 
between the equipment and receiver. 
- Connect the equipment into an outlet on a circuit different from that 
to which the receiver is connected. 
- Consult the dealer or an experienced radio/TV technician for help. 
- Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment. 
This device complies with Industry Canada license-exempt RSS 
standard(s). 
Operation is subject to the following two conditions: 
- This device may not cause interference, 
- This device must accept any interference, including interference 

Содержание RH-9180

Страница 1: ...LASER DISTANCE METER RH 9180 ...

Страница 2: ...itch Off 180s Unit Dimensions mm 105 41 24 mm Power Source 2 x AAA Batteries Measuring Unit m in ft ft in Storage Temperature 20 C to 60 C Operating Temperature 5 Cto 40 C Dimensions 113 47 5 30 2 Battery Life 10 000 Times Functions Distance Area Volume Pythagorean Continuous Measurement Add and Subtract Min Max Reading Timer Countdown Stake out Includes AAA 3 1 5V Textile Pouch PART LIST ...

Страница 3: ...stance meter x 1 2 AAA Battery x 2 3 Operation manual x 1 4 Carrying case x 1 5 Safety strap x 1 SAFETY INFORMATION This is a Class 2 laser tool laser radiation is emitted from this prod uct and is manufactured to comply IEC 60825 1 2007 EN 60825 1 2007 EN 61326 1 2013 and CRF21 parts 1040 10 and 1040 11 Use of controls adjustment procedures other than those specified herein may result in laser ra...

Страница 4: ...rference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Страница 5: ... Main Screen and units 10 Countdown measuring 11 Memories 12 Battery status 13 Sub Screen and units BATTERY INSTALLATION AND POWER STATUS 1 This unit is powered by 2 x AAA batteries 2 Remove battery lid and observing correct polarity before install batteries 3 Battery level is showed on screen with battery icon one screen BATTERY LIFE INDICATOR SYMBOLS 1 When the icon appears there are approximate...

Страница 6: ...fter 180 seconds 3 minutes MEASURING STARTING POINTS On the body of this device 4 points were designed in order to send laser beam 1 Spike Pin tail 2 Back of the unit 3 Tripod thread 4 Front of the unit STORE MEASUREMENT TO MEMORY AND LOOKUP When you want to add the measurements on the screen press to add to memory You could find the location in memory on the top of screen To lookup stored measure...

Страница 7: ...in 10 33 Area m ft ft ft ft ft ft P Volume m ft ft ft ft ft ft m BACKLIGHT LASER POINTER MODE Click and hold to turn on or off the backlight To enable laser pointer mode click and hold The laser indicator will display continuously until the mode is turned off STAKE OUT MEASUREMENT Stack out measurement help users to split a long distance into several piece equally The function need to be used in C...

Страница 8: ...ng in setting times 2 Click to set your preferred self trigger time 3 Timer could set from 3 seconds to 15 seconds 4 After the time is set press to activate measuring 5 After a beep the measured result appears on main screen MEASURING FUNCTIONS SINGLE MEASUREMENT MODE 1 Move the laser dot onto the target 2 Keep your position stable and click 3 The measurement will be displayed on LCD screen and la...

Страница 9: ...rement then click to save as Addend or to save as Minuend 3 Take the second measurement then click to add from addend or to subtract minuend AREA MEASUREMENT 1 Click to enable Area measurement 2 Laser will be activated when entering area measurement mode 3 Follow the instructions on main screen to measure WIDTH and LENGTH 4 After finish all the instructions the result AREA will be showed on screen...

Страница 10: ...RROR CODE Code Description Solution Error 01 Out of measuring range Measuring in a prop er range Error 02 Reflected signal is too weak Select a better surface Error 03 Out of display range Max Value 99999 e g result of area or di mension is out of display range Divide calculation into intermediate steps Error 04 Pythagorean calculation error Check and verify values and steps are correct Error 06 O...

Страница 11: ...ater Never use aggressive cleaning agents or solvents RECYCLING Batteries must not be disposed of with household waste Care for the environment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste ...