7
5.4) COFFEE DOSE ADJUSTMENT
In order to adjust the weight of the portion dispensed, use the increment/decrement
button control
s (“+” and “-“)
located on the top line near the display. After having set
the optimal degree of fineness, check the weight of the dose wit
h
a digital precision
scale. In order to adjust the dose, just select the dose you wish to adjust and hold
pressing the push button for 2.5 seconds; the display will blink and show the current
setting for the selected dose. By pressing the increment/decrement buttons “+” and “-“,
the grinding time can be increased or decreased and consequently the selected dose
can be increased or decreased. Approximately, a change of 0.1 seconds is equivalent
to a change of dose of 0.3 grams (0.01 ounces). After setting the desired amount of
grinding time, press the pre-selected push button again to confirm and save the data
set and exit from the adjusting program. Use a digital precision scale to check again
the weight of the dose and, if necessary, repeat above mentioned operation.
WHEN YOU ARE INSIDE THE AJUSTING PROGRAM, IT IS NOT POSSIBLE TO
OPERATE THE APPLIANCE.
IF THE APPLIANCE GETS SWITCHED OFF (SWITCH OFF OR POWER OFF)
BEFORE EXITING FROM THE AJUSTING PROGRAM, THE CHANGES ARE NOT
SAVED.
3 MINUTES MODE and MANUAL GRINDING MODE CANNOT BE
PROGRAMMED AND THE DOSES DISPLAY WILL NOT BE ADDED
DURING THESE TWO MODES.
WARM REMINDER:
In order to collect the portions of ground coffee, put the filter into holder under the
grounder outlet all the wa
y. The default setting for one dose is 7sec and 13sec for two