RH560WIRELESS CMS OPERATION MANUAL

Page 9/15

Notice

】:

After installation, the distance between sensor front and hose clamp is 8

10mm.

Warning

The machine should be stopped during installation.

4.5

Announcement for the first time using

When received new equipment, please try to connect with software MOS3000, make sure

the performance is good before installing on machine. Find a try area for installation, when chose
the the position for RH560

WL, please check the wireless communication RSSI value for the

farthest RH505, it requires that each sensor’s RSSI value should not lower than 20.

5. Equipment operating

5.1

Summarize

This system belongs to professional equipment, it requires for basic skills of the operators, in

order to ensure safe, correct and efficient using of this equipment, please read this manual
carefully before operating.

5.2

Announcements

After installation and configuration, please pay attention to the following:

Check the connection of power supply and earth wiring.

Check each component parameter setting.

Check the equipment fixing.

Make sure the working environment is suitable for the equipment.

Warning

】:

Please follow this manual strictly to operate this equipment, make sure all of the

steps were finished correctly.

5.3

RH560-WL Switch and LED description

Open RH560

WL cabinet cover, there is a switch with ON and OFF mark on main board, it is

power switch.

There are three indicators on RH560

WL, they are RUN (power indicator), COM

(communication indicator) and ERR (error indicator):

Indicat

ors

Status

Description

RUN

On

Power on

Off

Power off

Содержание RH560-WL

Страница 1: ...RH560WIRELESS CMS OPERATION MANUAL 第 1 页 共 15 页 RH560 WL Wireless CMS User Manual ANHUI RONG ZHI RI XIN INFORMATION TECHNOLOGY CO LTD 2016 03 ...

Страница 2: ... 6 4 2 Out of box audit 6 4 3 Installation announcements 7 4 4 Installation 7 4 4 1 RH560 WL Installation 7 4 4 2 RH505 Installation 8 4 4 3 RH509 Installation 8 4 5 Announcement for the first time using 9 5 Equipment operating 9 5 1 Summarize 9 5 2 Announcements 9 5 3 RH560 WL Switch and LED description 9 6 Software user manual 10 6 1 Summarize 10 6 2 User login 10 6 3 Software configuration 11 6...

Страница 3: ...might be occurred if there is improper operating 2 Product introduction 2 1 Summarize 1 RH560 WL WIRELESS CMS is positioned on industrial enterprises which is developed by RONDS Company for scattered measuring points and unavailable wiring work It integrates vibration temperature and speed signals 2 System hardware includes RH560 WL wireless collection station RH505 wireless vibration temperature ...

Страница 4: ...er MOS3000 support for multiple DAQ parameter sending 2 Wireless collection station will update the DAQ parameter after receiving from MOS3000 software 3 RH505 and RH509 sensor will receive DAQ parameters after power on and then collect data accordingly these data shall be sent to RH560 WL wireless collection station through Zigbee 4 RH560 WL wireless collection station receives data from every wi...

Страница 5: ... of both constant and variable speed rotating machines Low consumption design IP66 protection degree EXIA intrinsic safety certified can be sued for special industries like petrochemical and mining field Internal antenna more reliable in industrial field 2 5 Technical specifications RH560 WL Wireless data collector Input and output Communication with Sensor 2 4GHz IEEE 802 15 4 Indicator LED Total...

Страница 6: ...onal training is not allowed to disassemble and repair this equipment RONDS is not responsible for the accidents that caused by this kind of operating Correctly configure parameter with products and connect power supply Make sure there is earth wiring for power supply and check the reliability Please contact with RONDS if any problems Notice Please contact RONDS company if any questions or suggest...

Страница 7: ...al training Danger Please make sure the security when using 220V power supply in case of any human injury Danger When install sensors on the surface of the machine please make sure the machine is stopped 4 4 Installation 4 4 1 RH560 WL Installation a Fixing method RH560 WL has two methods of fixing Hanging and fixation though holder Users can choose one of them according to the actual situation Th...

Страница 8: ...h M6 screw and magnet base on the surface of machines the torque of RH505 is 8N Notice Before install the magnet base please clean the measuring point position greasy dirt or dust is not allowed Notice RH505 should be fixed after the glue is solidified completely Notice The cover of RH505 should be fixed well Warning If the installation is improper it will cause incorrect data diagnostic conclusio...

Страница 9: ...s for basic skills of the operators in order to ensure safe correct and efficient using of this equipment please read this manual carefully before operating 5 2 Announcements After installation and configuration please pay attention to the following Check the connection of power supply and earth wiring Check each component parameter setting Check the equipment fixing Make sure the working environm...

Страница 10: ...software is monitor the data collected by RH560 WL then provide detailed data analysis information Please install SQL database and MOS3000 online monitoring software at the same time MOS3000 will generate 3 programs MOS3000 Online monitoring system MOS3000 System configuration tool and Online service Notice When configure parameter of MOS3000 System configuration tool and online service please mak...

Страница 11: ... be a tick mark 6 3 Software configuration 1 Choose System configuration right click Root to create Organization Machine Measuring point and DAQ definition The information of Organization Machine and Measuring point can be edited RH560 WL system support for 3 measurement definition maximally data length and Fmax can reach to 256K and 20KHz respectively ...

Страница 12: ...ype RH560 WL 2 Server name choose the right database to store data or create new database in the popup windows 3 Collection station code input the last four number 4 Collection method variable speed or constant speed test mode is forbidden 5 Monitoring machine click it to add relative machines 6 Associate measuring point ...

Страница 13: ...d information please refer to MOS3000 Online monitoring software user manual 6 5 Software abnormal processing 1 Can t login software a please check the SQL database and local server is working normally or not b Please check the online service and configuration service is started or not 2 Failed to send DAQ definition Please check if the data collector is displayed in the online service 3 No collec...

Страница 14: ...data is not correct Low battery voltage of RH505 Check battery condition from online service FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modific...

Страница 15: ...ipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator your body ...