![Ronde & Schwarz 1304.0004K03 Скачать руководство пользователя страница 717](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004k03/1304-0004k03_user-manual_1484987717.webp)
Remote Commands
R&S
®
FPL1000
717
User Manual 1178.3370.02 ─ 11
10.6.13
Measuring the AM Modulation Depth
All remote control commands specific to AM modulation depth measurements are
described here.
Configuring and Performing the Measurement
..................................................... 717
Example: Measuring the AM Modulation Depth
....................................................718
10.6.13.1
Configuring and Performing the Measurement
The following commands control the measurement.
Useful commands for AM modulation depth described elsewhere
●
●
CALCulate<n>:DELTamarker<m>:X:RELative?
●
Remote commands exclusive to AM modulation depth measurements
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe]
................................................... 717
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE
............................... 717
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:RESult<t>?
..............................................718
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth[:STATe]
<State>
This command turns the AM Modulation Depth measurement on and off.
To work correctly, the measurement requires an AM modulated signal.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
CALCulate<n>:MARKer<m>:FUNCtion:MDEPth:SEARchsignal ONCE
This command initiates a search for the signals required for the AM depth measure-
ment.
Note that the command does not perform a new measurement, but looks for the sig-
nals on the current trace.
Suffix:
<n>
.
<m>
Configuring and Performing Measurements