![Ronde & Schwarz 1304.0004.03 Скачать руководство пользователя страница 316](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985316.webp)
The Spectrum Application (RF Measurements)
R&S
®
FPL1000
316
User Manual 1178.3370.02 ─ 09
2. Use the "Auto Level" function ([AUTO] menu) to optimize the reference level.
3. Use the "AF Auto Scale" function ([AUTO] menu) to optimize the scaling.
4.
To determine a precise level at a specific point in the signal:
● Reduce the "Range" of the y-axis to a small area around the required level. If
necessary, change the "Ref Level Position" so the required range remains visi-
ble.
● Select "Linear with Unit" scaling.
Now you can set a marker at the point in question and read the result.
5.
To detect a spurious signal close to the noise floor:
● Set the "RF Attenuation" to "Manual" mode and reduce the "Value" to lower the
noise floor.
● Select "Relative" - "Logarithmic" scaling.
Now you can determine if any spurious levels of a certain size are visible.
7.6
Bandwidth, Filter and Sweep Configuration
The basic bandwidth, filter and sweep settings that apply to most measurements are
described here. These parameters define how the data is measured: how much data is
collected internally and which filters are used.
Impact of the Bandwidth, Filter and Sweep Settings
.............................................316
Bandwidth, Filter and Sweep Settings
.................................................................. 321
Reference: List of Available RRC and Channel Filters
......................................... 330
7.6.1
Impact of the Bandwidth, Filter and Sweep Settings
The bandwidth, filter and sweep settings are closely related and interdependent. The
values available for resolution bandwidth and video bandwidth depend on the selected
filter type. In addition, these settings have an impact on other measurement parame-
ters. The following equation shows the interdependency of these settings:
T
MIN
= K*Span/RBW
2
where K = Filter constant
By default, a Gaussian filter is used. The resolution bandwidth, the video bandwidth
and the "Sweep Time" are set automatically according to the set span, and default cou-
pling is used. Thus, the following settings are applied:
RBW = 100 * Span
VBW = RBW = 100 * Span
"Sweep Time" = T
min
for set Span, RBW, VBW
Bandwidth, Filter and Sweep Configuration