Page 3
Safety warnings
For your own and other’s safety please read this USER’S MANUAL and follow its
instructions carefully.
△
Danger
1.
Never use the heater where flammable vapors may be present, there is danger of
explosion, fire and burning
。
2.
Always provide adequate ventilation during the use. Only use the appliance in well
ventilated area, the air must be regular exchanged during the use (two times/one
hour), inadequate burning caused by oxygen shortage can cause carbon
monoxide poisoning.
3.
Minimum ventilation requirements: When the appliance is used in inner room,
make sure the room space is no less than 330 m³ and the average air-circulation
opening area is no less than 825cm²
4.
When gas leakage happens, firstly cut off the gas supply resource, then open all
ventilation equipments, use more fan to dilute the leak out gas,
(
attention
:
do not
use equipment which can cause sparkles when the leakage gas was not adequate
diluted.
)
5.
Do not put the machine in basement or use it under ground level, to avoid danger.
△
Warning
1.
The appliance shall not be directed towards the gas cylinder
2.
Don’t use spay products at the location where the heater is used
,
the gas from the
spay tin can cause danger of fire and explosion.
3.
Don’t use the appliance in place with combustible powder
(
wastepaper, wood
crumbs, fibre scraps
),
if these powder are sucked in the heater and heated up,
flake and spark may be ejected out and cause fire and burning danger.
4.
Never block air inlet or heating part
,
it can cause abnormal burning and fire.
5.
Never modify the heater, alteration may cause malfunction and fire, is very
dangerous
6.
This appliance is only for heating use in public area, should not be used for
household heating.
△
Attention
1.
In order to prevent fire while in operation, please don’t place articles near the
heater. Keep all combustible materials away from heater. Minimum clearances:
Outlet (front) 3.5M
,
air inlet (rear) 2M
,
top 2M
,
side 2M.
2.
While
in
operation
,
make sure
that
the
ground
surface
does
not
overheat
,
overheating may cause fire.
3.
Do not fill fuel tank while heater is in operation, make sure the heater stopped and
the flame extinguished before you fill the tank. Filling while in operation may result
Содержание K-30