1.4
Clearance from Combustible Walls
There are listed clearances for your stove which were determined in a laboratory test, using various “classes” of stove pipe
or chimney. Minimums are first established for the stove itself and then increased, based on how much heat i s transferred
by each class of pipe.
Residential Standard (not approved for manufactured [mobile] homes)
Using single wall pipes connector to the top of the woodstove.
Clearances – USA & Canada (inches / millimeters)
A:
18 / 460
C:
18 / 460
E:
18 / 460
B:
15 / 380
D:
5 /
1
30
PROTECTED WALL CLEARANCE
If the woodstove is installed adjacent to a protected wall system, the variance must be approved by your local building
official. Normally, the protected wall system is defined as a non -combustible material, with a minimum of 1” air space
behind it. Check your local building codes or consult a qualified installer (Ref. NFPA 211).
WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES.