Observe the
grounding regulations
Fire and
smoke prohibition
The stay for
persons with
cardiac pacemakers
is forbidden
Static charges
Static charges can have the following consequences: Charges to people,
electric shocks, sparking. Charging of objects must be avoided by a pro-
per grounding.
Grounding
All electricity conducting parts found in the workplace of 5 meters around
each booth opening, and particularly the objects to be coated, have to
be grounded. The earthing resistance of each object must amount to
maxi-mally 1 MOhm. This resistance must be checked/tested regularly
when starting work.
The condition of the work piece attachments, as well as the hangers,
must guarantee that the work pieces remain grounded. The appropriate
measuring devices must be kept ready in the workplace, in order to
check the grounding.
The floor of the coating area must conduct electricity (normal concrete is
generally conductive).
The supplied grounding cable (green/yellow) must be connected to the
grounding screw of the electrostatic manual powder coating equipment.
The grounding cable must have a good metallic connection with the coat-
ing booth, the recovery unit and the conveyor chain, respectively with the
suspension arrangement of the objects.
Smoking and igniting fire are forbidden in the entire plant area! All spark-
generating works are forbidden!
As a general rule for all powder spraying installations, persons with pa-
cemakers should never enter high voltage areas or areas with electro-
magnetic fields. Persons with pacemakers should not enter areas with
powder spraying installations!