9 Deforest St. Amityville NY, 11701
1-631-842-2400
romanoff.com
18
HOLD (SOAK) TIME
“HOLD” or “SOAK” time means heat-soakingthe flasks at the end of each segment. You can hold the
temperature in each segment up to 99 hours and 99 minutes.
PRESENT STATUS
“PRESENT STATUS” shows where the furnace is during firing. This is specially useful for firing that have
heating-upand cooling-downsegments. To use “PRESENT STATUS”, press 5 on the key board during a
firing. The current segment will display momentarily.
SKIP SEGMENT
“SKIP SEGMENT” worksonly duringfiring.To skip a segment, press 9 on the keyboard. [ SstP ] will display
(if you change your mind and do not want to skip the segment, do nothing and the firingwill continue as it
was). If you still want to skip the segment after pressing 9, press ENTER and [ rA ] will appear along with the
segment number you just skipped to.
DELAY FIRE
The “DELAY FIRE” programs the furnace to start its firing run (burnout) at a later time. It zeroes out after
each completed firing. To use the “DELAY FIRE” again, you need to reset it each time you start. Enter the
“DELAY FIRE” after you have chosen your programand you reach [ IdLE ] on the display. Press 3 on your
key board. Enter the delay in hours and minutes (such as 3 hours and 45minutes is 345-your display will
show [ 03.45 ] ) and the press ENTER. The display will then alternately display [ dELA ] and the time
remaining for the delay.
WARNING: NEVER LEAVE YOUR FURNACE UNATTENDED NEAR THE END OF A FIRING. WE CANNOT
GUARANTEE YOUR FURNACE AGAINST OVERFIRING EVEN THOUGHTHE CONTROLLER IS AUTOMATIC.
THE OPERATOR ASSUMES FULL RESPONSIBILITY FOR TURNINGTHE FURNACE OFF AT THE PROPER
TIME.
REPEAT FIRINGS & PROGRAM REVIEW
To repeat last firing, just press ENTER from [ ldLE ]. The furnace will begin firing, but first, use your
PROGRAM REVIEW to makesure you are using the correct program.To startPROGRAM REVIEW press6on
the key board. Values for the last program used will be displayed one after another. You can also use
PROGRAM REVIEW during firing simply by pressing 6 on the key board.
SETTING THE ALARM BEFORE FIRING BEGINS
The alarm beeps when a preset temperature is reached.
1) At any time, press 7 on the key board. [ AlAr ] will appear alternating with the last alarm temperature
entered.
2) Enter the new alarm temperature. Then press ENTER. [ ldLE ] willappear or the currentrunningprofilewill
continue.
3) To turn alarm off enter 9999.
When the alarm sounds during firing, shut it off by pressing any key. If it sounds as soon as the furnace
begins firing it is due to the fact that the alarm was set to 0000.