Roma R-1000 Скачать руководство пользователя страница 4

INTERCONNECTIONS 

 
 

Note: Power must remain off until all connections are completed

 

Keypad 

 
A cable is provided for the keypad and the power unit connections. 
Tightly insert one end of the cable onto the keypad as shown in figure 2.Connect the 
cable’s other end to the power unit as shown on the wiring diagram. 
 

Temperature Probe 

 
Connect the temperature probe cable to the power unit as shown on the wiring diagram. 
 

 

WIRING INSTRUCTIONS 

 
SEE WIRING DIAGRAM FOR EXACT CONNECTIONS. 
 
The power unit has two wire cables labeled 120VAC input, and 120VAC output. 
 
(1) Run the black wire from 120VAC input to the #1 terminal of the 4 port terminal 
block. 
 
(2) Run the white wire of the 120VAC input to the #2 terminal of the 4 port terminal 
block. 
 
(3)  Run the black wire from the 120VAC output to the #3 terminal of the 4 port terminal 
block. 
 
(4) Run the white wire of the 120VAC output to the #4 terminal of the 4 port terminal 
block. 
 
 
Connect all ground wires to the ground lug provided – see main wiring diagram. 
  
  
  
 
 
 
 
 

 

 

 

 

 

 

 

 

 